Mitsubishi Electronics MR-MC210 Manuel D’Utilisation
6 - 143
6. APPLICATION FUNCTIONS
6.31.7 Combinations of continuous operation to torque control and other functions
The following shows the combinations of continuous operation to torque control with each function.
Classification Function Compatibility
Remarks
System
function
function
SSCNET
communication
method
communication
method
SSCNET /H
SSCNET
Control mode
Standard mode
Interface mode
Operation
function
function
JOG operation
—
Incremental feed
—
Automatic operation
Automatic switch/Manual switch can be selected.
Linear interpolation
Linear
interpolation
. When starting up a
continuous operation to torque control point,
"continuous operation to torque control error
(operation alarm 5D, detail No.0A)" occurs.
"continuous operation to torque control error
(operation alarm 5D, detail No.0A)" occurs.
Home position return
—
Home position reset function
—
Application
function
function
Command unit Electronic gear
Speed unit
Speed unit
Set the continuous operation to torque control
speed limit value in speed units.
speed limit value in speed units.
Speed units multiplication factor
Speed limit
The continuous operation to torque control speed
limit value is restricted by speed limit value
(control parameter No.0222, No.0223)
limit value is restricted by speed limit value
(control parameter No.0222, No.0223)
Acceleration/
deceleration
deceleration
Linear acceleration/deceleration
Smoothing filter
Invalid during continuous operation to torque
control.
control.
Start up speed validity
Valid when starting up operation point. However, it
is invalid during continuous operation to torque
control.
is invalid during continuous operation to torque
control.
S-curve acceleration/deceleration
(Sine acceleration/deceleration)
(Sine acceleration/deceleration)
Invalid during continuous operation to torque
control.
control.
Servo off
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Forced stop
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Stop operation
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Rapid stop operation
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Limit switch (stroke end)
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Software limit
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Interlock
Control mode is automatically changed to position
control mode after an operation alarm occurrence.
control mode after an operation alarm occurrence.
Rough match output
At continuous operation to torque control points
the rough match turns ON when the distance
remaining based on the position data of the point
table is within the rough match output range.
the rough match turns ON when the distance
remaining based on the position data of the point
table is within the rough match output range.
Torque limit
During continuous operation to torque control and
torque limit, torque limit stays OFF.
torque limit, torque limit stays OFF.
: Usable : Unusable : Restriction —: Not applicable