9.6 Interrupt output cycle
When several buffer are used in interrupt valid, and interrupt output for every control cycle is not needed, the
cycle of interrupt output can be changed by the interrupt output cycle of Interface mode option (parameter
No.000F).
(1) System parameters
cycle of interrupt output can be changed by the interrupt output cycle of Interface mode option (parameter
No.000F).
(1) System parameters
Parameter
No.
Abbreviation Name Initial
value Units
Setting
range
Function
000F *IFMO
Interface
mode
option
mode
option
0000h
0000h
to
0F0Fh
0
0 0
Interrupt output cycle
When interrupt by interface mode
is valid, set the cycle for which
the interrupt is output.
Interrupt output cycle:
When interrupt by interface mode
is valid, set the cycle for which
the interrupt is output.
Interrupt output cycle:
Control cycle (setting value+1)
Example: When interrupt output cycle
is set to 1 and control cycle
is 0.88ms, interrupt is output
approximately every 1.77ms.
is set to 1 and control cycle
is 0.88ms, interrupt is output
approximately every 1.77ms.
(2) Interrupt output cycle
The relationship between interrupt output cycle and control cycle is shown in the table below.
Setting
value 0 1 2 3
8
15
Control
cycle
0.88ms 0.88ms 1.77ms 2.66ms
3.55ms
8.00ms
14.22ms
Control cycle 0.44ms
0.44ms
0.88ms
1.33ms
1.77ms
4.00ms
7.11ms
Control
cycle
0.22ms 0.22ms 0.44ms 0.66ms
0.88ms
2.00ms
3.55ms