Creating and Configuring Application Signatures
22
EMC Smarts Application Connectivity Monitor Configuration Guide
S p e c i f y i n g P o r t N u m b e r , R e q u e s t , a n d R e s p o n s e
P a r a m e t e r s
The Port Number, Request, and Response parameters can provide various
types of information depending upon the entered values.
types of information depending upon the entered values.
If, for example, you only need to know whether you can connect to a
specified port, enter that port number.
specified port, enter that port number.
Port Number <25> (for SMTP)
Request <No Value>
Response <No Value>
If, however, you need to know whether you can connect to a specified port
and that the server should respond with a certain pattern, then enter a port
number and response string.
and that the server should respond with a certain pattern, then enter a port
number and response string.
Port Number <25>
Request <No Value>
Response <*sendmail*>
Finally, you can enter values for all three parameters to send a request to
induce the server to respond with a particular pattern.
induce the server to respond with a particular pattern.
Port Number <80> (for a Web Server)
Request <GET HTTP/1.0\n\n>
Response <*Server: Apache*> (to detect an Apache Web Server)
Monitoring Action
The monitoring action to be used to monitor the
discovered application. The default is tcpAction. The
values for parameters in the monitoring action can be
specified by clicking the Customize… button. See
for additional information.
If <None> is selected in the drop down list, the
If <None> is selected in the drop down list, the
applications discovered by the application signature
will not be monitored.
Optional
System Name Pattern
The system name pattern(s) of the systems against
which the application signature should be run. The
values for the pattern(s) can be specified by clicking
the Customize...button. See
on page 25 for additional information.
Wild card criteria specification is supported. See
for additional information.
The default is “*” which means that the system will
The default is “*” which means that the system will
discover a specified application on all systems added
to the ACM Domain Manager’s topology.
Required
Table 4:
Application Signature Fields (continued)
F
IELD
N
AME
D
ESCRIPTION
R
EQUIRED
/O