Cisco Systems 78-10588-03 Manuel D’Utilisation

Page de 30
Chapter 3
Installing the Chassis
Removing the Power Supply Module
3-24
Cisco Metro 1500 Series Hardware Installation Guide
78-10588-03
Figure 3-11 Rear View of Power Supply Module
All PSMs are hot-swappable and can be replaced while the system is in service.
To replace a PSM, follow these steps:
Step 1
Remove the power cord associated with the failed power supply and loosen the
four panel screws.
Step 2
Pull out the malfunctioning module.
Step 3
Slide in the spare module.
Step 4
Check that the green LED is on.
Step 5
Reconnect the power cord.
Step 6
Tighten the four panel screws.
Voltage:
Max. Current:
Power Consumption:
Fuse:
For continued protection against risk of fire replace
only with same type and ratings of fuse.
For proper selection of power supply cord refer to
instruction manual.
Made in Germany
March 1998                                 
Always remove both 
power cords when dis-
connecting from power
source 1.
!
115/230 V 50/60 Hz
2.5 A
max. 100W
2x T2.5A / 250V
Fan module
DC Power
connectors
Fuse
holders
32268
Fuse 1
Fuse 2
Power 1
Power 2