Graco 3A2079A Manuel D’Utilisation
Connecting an RS Gun to an LPA2 System
3A2079A
3
Parts Included in Kit 125843
Installation
1.
Install fitting 7596-02 (ref. 3) into the air
manifold (B).
manifold (B).
2.
Remove the check valve (C) from the catalyst pump
assembly (A) then install into fitting 7596-02 (ref. 3).
assembly (A) then install into fitting 7596-02 (ref. 3).
3.
Install fitting LPA-143 (ref. 4) onto the check
valve (C) removed in the previous step.
valve (C) removed in the previous step.
4.
Remove the old catalyst pump connection hose
from catalyst pump outlet (D).
from catalyst pump outlet (D).
5.
Install fitting 22017-01 (ref. 2) into catalyst pump
outlet (D).
outlet (D).
6.
Install fitting 124803 (ref. 1) into fitting
220127-01 (ref. 2).
220127-01 (ref. 2).
7.
Connect and configure air, material and catalyst
hoses. See RS Gun manual 3A0232 for detailed
instructions.
hoses. See RS Gun manual 3A0232 for detailed
instructions.
Ref
Part
Number
Description
Qty
Fitting
1
124803
JIC 04 (male) x
1/8 NPT (male)
1/8 NPT (male)
1
2
22017-01
1/4 tube (male) x
1/8 npt (female)
1
3
7596-02
3/8 npt (male) x
1/4 npt (female)
1/4 npt (female)
1
4
LPA-143
1/4 tube (female) x
1/4 npt (female)
1
To reduce the risk of skin injection from high pressure
fluid, perform Pressure Relief Procedure before
connecting fittings. See RS gun manual 3A0232.
fluid, perform Pressure Relief Procedure before
connecting fittings. See RS gun manual 3A0232.