Graco 3A2079A Manuel D’Utilisation

Page de 4
Connecting an RS Gun to an LPA2 System
3A2079A
3
Parts Included in Kit 125843
Installation  
1.
Install fitting 7596-02 (ref. 3) into the air 
manifold (B).
2.
Remove the check valve (C) from the catalyst pump 
assembly (A) then install into fitting 7596-02 (ref. 3).
3.
Install fitting LPA-143 (ref. 4) onto the check 
valve (C) removed in the previous step.
4.
Remove the old catalyst pump connection hose 
from catalyst pump outlet (D).
5.
Install fitting 22017-01 (ref. 2) into catalyst pump 
outlet (D).
6.
Install fitting 124803 (ref. 1) into fitting 
220127-01 (ref. 2).
7.
Connect and configure air, material and catalyst 
hoses. See RS Gun manual 3A0232 for detailed 
instructions.
Ref
Part 
Number
Description
Qty
Fitting
1
124803
JIC 04 (male) x
1/8 NPT (male)
1
2
22017-01
1/4 tube (male) x 
1/8 npt (female)
1
3
7596-02
3/8 npt (male) x 
1/4 npt (female)
1
4
LPA-143
1/4 tube (female) x 
1/4 npt (female)
1
To reduce the risk of skin injection from high pressure 
fluid, perform Pressure Relief Procedure before 
connecting fittings. See RS gun manual 3A0232.