Carrier 38AK012 Manuel D’Utilisation

Page de 16
5
UNIT 38
DIM. A
DIM. B
DIM. C
DIM. D
DIM. E
DIM. F
AK007
1
′-6
1
/
2
[470.0]
1
′-2
3
/
4
[375.0]

1
′-2
1
/
4
[362]
1
′-4
5
/
16
[415]
2
′-9
5
/
16
[846.5]
AK008
1
′-8″
[508.0]
1
′-6
1
/
2
[470.0]

1
′-3″
[381]
2
′-
5
/
16
[613]
3
′-5
7
/
16
[1052.5]
AK012
1
′-9″
[533.4]
1
′-8″
[508.0]
2
′-0″
[609.6]
1
′-3″
[381]
2
′-
5
/
16
[613]
3
′-5
7
/
16
[1052.5]
AKS008
1
′-6″
[457.2]
1
′-4
3
/
4
[425.5]
2
′-9
13
/
16
[858.8]
1
′-3″
[381]
2
′-
5
/
16
[613]
3
′-5
7
/
16
[1052.5]
AKS009
1
′-7″
[482.6]
1
′-5″
[431.8]
2
′-9
13
/
16
[858.8]
1
′-3″
[381]
2
′-
5
/
16
[613]
3
′-5
7
/
16
[1052.5]
AKS012
1
′-7″
[482.6]
1
′-5″
[431.8]
2
′-9
13
/
16
[858.8]
1
′-3″
[381]
2
′-
5
/
16
[613]
3
′-5
7
/
16
[1052.5]
NOTES:
1. Dimensions in [
 ] are in millimeters.
2.
Center of Gravity. See chart for 
dimensions.
3.
Direction of Airflow.
4. Minimum clearance (local codes or jurisdiction
may prevail):
a. Condenser coil, for proper airflow, 36 in. [914]
one side, 12 in. [305] the other. The left or rear
side getting the greater clearance is optional.
b. Overhead, 60 in. [1524] to assure proper con-
denser fan operation.
c. Between units, control box side, 42 in. [1067]
per NEC (National Electrical Code) (U.S.A.
Standard).
d. Between unit and ungrounded surfaces, con-
trol box side, 36 in. [914] per NEC.
e. Between unit and block or concrete walls and
other grounded surfaces, control box side,
42 in. [1067] per NEC.
5. With the exception of the clearance for the con-
denser coil as stated in Note 4b, a removable
fence or barricade requires no clearance.
6. Units may be installed on combustible floors
made from wood or Class A, B, or C roof covering
material.
ELECTRICAL CONNECTIONS
SERVICE VALVE CONNECTIONS — 50/60 Hz
CONNECTION SIZES
AA
1
3
/
8
″ Dia [35] Field Power Supply Hole
BB
2
″ Dia [51] Power Supply Knockout
CC
2
1
/
2
″ Dia [64] Power Supply Knockout
DD
7
/
8
″ Dia [22] Field Control Wiring Hole
UNIT 38
SUCTION
LIQUID
AK007
1
1
/
8
″ [28.6]
1
1
/
2
″ [12.7]
AK008
1
1
/
8
″ [28.6]
1
1
/
2
″ [12.7]
AK012
1
1
/
8
″ [28.6]
1
5
/
8
″ [15.9]
AKS008
1
1
/
8
″ [28.6]
1
1
/
2
″ [12.7]
AKS009
1
1
/
8
″ [28.6]
1
5
/
8
″ [15.9]
AKS012
1
1
/
8
″ [28.6]
1
5
/
8
″ [15.9]
Fig. 2 — Dimensions (ft-in.)
Fig. 3 — Rigging Label
*Weights are for aluminum coils.
UNIT
38
RIGGING
WEIGHT*
A
B
C
lb
kg
in.
mm
in.
mm
in.
mm
AK007
390
176
45.0
1143
38.5
978
35.5
904
AK008
442
200
45.0
1143
38.5
978
43.5
1105
AK012
476
215
45.0
1143
38.5
978
43.5
1105
AKS008
560
254
45.0
1143
38.5
978
43.5
1105
AKS009
614
279
45.0
1143
38.5
978
43.5
1105
AKS012
614
279
45.0
1143
38.5
978
43.5
1105