9. Wipe out the cylinder using an all-purpose 
cleaner or detergent and water solution. Refer to 
Figure 5.
Figure 5
If the tumbler does not meet ANY of the listed 
requirements, remove tumbler from use. Refer to 
Removing Tumbler from Service section
Required for CE Models Only
Once machine is installed, please be sure to complete 
the following items:
• Review and verify machine operation with 
customer.
• Leave all literature and a signed Declaration of 
Conformity with customer.
• Review machine warranty information with 
customer.
• Apply warning sticker on front panel of machine, 
in language appropriate to country of sale 
(included in literature packet).
Installing CE Gas Drying Tumblers
General Information
This information is to be used when installing gas 
tumblers in countries, and/or on gases, different than 
the machine’s factory configuration. Tumblers are 
supplied from the factory for operation on Natural Gas 
1000 Btu/cu ft. (8914 kcal/m
3
), or L.P. Gas 2500 Btu/
cu ft. (22,250 kcal/m
3
) in the countries of GB/IE/PT/
ES/IT/GR/LU/CH. To install machines in any other 
country, or on any other gas, requires some level of 
modification.
Burner orifices, stickers, block-open kits, regulator 
springs and other parts needed for conversions are to 
be ordered separately.
Models are built in two different configurations:
• Regulated Natural Gas – Burner orifice is sized 
for Natural Gas, second family, group H (E) at 
20 mbar inlet pressure. Regulator/governor is 
operational. Gas valve CAN be field-converted to 
a non-regulating type.
• Unregulated L.P. (Liquefied Petroleum) Gas – 
Burner orifice is sized for L.P., third family, 
group 3+ at 28.37 mbar inlet pressure. Regulator/
governor is blocked open. Gas valve CANNOT 
be field-converted to a regulating type.
Serial plates supplied from the factory are configured 
for the countries of GB/IE/PT/ES/IT/GR/LU/CH. 
These instructions pertain to the situations when the 
country of use or gas supply is different than that on 
the serial plate.
T452I
T452I
WARNING
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the 
tumbler before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002