Sterling DH1-610-2 Manuel D’Utilisation

Page de 63
Chapter 4:  Operation 
4-1 
Controller Description and Operation 
Identifying Control Panel Components for the AP-1 Controller 
Disconnect Switch 
The Disconnect Switch is located in the front upper right hand corner of the control 
enclosure.  It allows the user to disconnect power to the dryer for emergency shutdown, 
service or long periods of inactivity. 
Control Power Switch 
The Control Power Switch is located on the front of the control enclosure below the touch 
screen.  The switch energizes the control circuit (PLC, touch screen, relays, etc.) within the 
control enclosure. 
Touch Screen 
The Touch Screen is located in the center of the control enclosure.  Once the disconnect is 
on and the control circuit is energized, the machine can be started and parameters can be 
adjusted through the touch screen.  
Alarm Horn & Light 
The Alarm Horn is located in the center of the control enclosure, next to the Control Power 
Switch.  The Alarm Light is located on the top of the enclosure.  These devices give an 
audible and visual indication that there is a malfunction with the system. 
Figure 3:  Typical Control Panel 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Portable Drying/Conveying Systems 
Chapter 4:  Operation 
21 of 63