4.  Thread a UL approved 30 Amp power cord. NEMA 14-30 type ST or SRDT  
through the strain relief.
5.  Attach the green power cord ground wire to the cabinet with green ground 
screw.
6.  Attach the white (neutral) power cord conductors and the green ground wire 
from the dryer harness to the brass-colored center terminal on the terminal 
block. Tighten the screw securely.
7.  Attach the red and black power cord conductors to the outer brass-colored 
terminals on the terminal block.  
WARNING:  Do not make a sharp bend or crimp the wiring /conductor at 
connections.
8. Tighten the screws securing the cord restraint firmly against the power cord.
9. Tighten the strain relief nut securely so that the strain relief does not turn.
10. Reinstall the terminal block cover. 
GAS DRYER (GDG450AW) 
NOTE:  DO NOT connect the dryer to L.P. gas service without converting the 
gas valve. An L.P. Conversion Kit must be installed by a qualified gas 
technician. 
1.  Remove the shipping cap from gas pipe at the rear of the dryer. 
2.  Connect a 1/2 inch (1.27cm) I.D. semi-rigid or approved pipe from gas 
supply line to the 3/8 inch (0.96cm) pipe located on the back of the dryer. 
Use a 1/2 inch to 3/8 inch (1.27cm to 0.96cm) reducer for a connection. 
Apply an approved thread sealer that is resistant to the corrosive action of 
liquefied gases on all pipe connections. 
3. Open the shutoff valve in the gas supply line. 
4.  Test all connections by brushing on a soapy water solution. NEVER TEST FOR 
GAS LEAKS WITH AN OPEN FLAME. 
5.  Connect the exhaust duct to the outside exhaust system. Use duct tape to seal 
all joints. 
6.  With the dryer in its final position, adjust one or more of the legs until the 
dryer is resting solid on all four legs. Place a level on top of the dryer. THE 
DRYER MUST BE LEVEL AND RESTING SOLID ON ALL FOUR LEGS. 
7.  Plug the power cord into a grounded outlet. NOTE: check to ensure power is 
Off at circuit breaker/fuse box before plugging the power cord into the outlet. 
 GAS CONNECTIONS
CAUTION