maintain a minimum of 12 inches (30.5cm) clearance between the vent hood 
and the ground or any other obstruction. The vent flap should be able to move 
freely, although vertical orientation of the exhaust system is acceptable. Certain  
extenuating circumstances could affect the performance of the dryer: 
   1. Only rigid metal duct work should be used.
   2.  Venting vertically through a roof may expose the exhaust system to down 
drafts causing an increase in vent restriction.
   3.  Running the exhaust system through an uninsulatedarea may cause 
condensation and faster accumulation of lint.
   4.  Compression of crimping of the exhaust system will cause an increase in  
vent restriction.
    The exhaust system should be inspected and cleaned a minimum of every 12 
months with normal usage. The more the dryer is used the more often you 
should check the exhaust system and vent hood for proper operation.
English
8
RECOMMENDED MAXIMUMM
Exhaust Hood Types
Recommended
Use only for short  
run installations
No. of 90º 
elbows
Rigid Metal
Flexible Metal
Rigid Metal
Flexible 
Metal
0
90 ft.
55 ft.
60 ft.
45 ft.
1
60 ft.
40 ft.
45 ft.
30 ft.
2
45 ft.
30 ft.
35 ft.
20 ft.
3
35 ft.
20 ft.
25 ft.
15 ft.