Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes or 
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to 
open fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 cm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered.
Installation spacing for custom undercounter installation
Custom undercounter installation - Dryer only
*Required spacing
Closet installation - Dryer only
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
Recessed or closet installation - Dryer on pedestal
*Required spacing
**For side or bottom venting, 0" (0 cm) spacing is allowed.
      38"
(96.52 cm)
 *31½"
(80 cm)
     27"
(68.6 cm)
     51½"
(130.81 cm)
A. Side view - closet or confined area
B. Closet door with vents
A. Recessed area
B. Side view - closet or confined area
    0"
(0 cm)
    1"*
(2.5 cm)
    1"*
(2.5 cm)
  38" min.
(96.52 cm)
     27"
(68.6 cm)
A
B
14" max.*
(35.6 cm)
18" min.*
(45.72 cm)
    1"*
   5"**
(12.7 cm)
   31½"
(80 cm)
48 in.
2* 
(310 cm
2
)
24 in.
2*
(155 cm
2
)
      3"*
(7.6 cm)
      3"*
(7.6 cm)
    (2.5 cm)
A
B
    1"
(2.5 cm)
   1"
(2.5 cm)
    1"*
(2.5 cm)
    5"**
  (12.7 cm)
        27"
   (68.6 cm)
  31½"
(80 cm)
 18" min.*
(45.72 cm)
14" max.*
(35.6 cm)