IBM 578 Manuel D’Utilisation

Page de 70
__ 1.
Open the back cover on your 5079. See Appendix A, “Removing the back
covers” on page 31 
if you need instructions.
__ 2.
Connect the cables to 5079–002 (the upper unit). See Appendix B,
“Connector Locations” on page 35 
if you need information about finding
connectors.
__ a.
Connect a new HSL cable to HSL connector 0.
__ b.
Connect a new HSL cable to HSL connector 1. If you have different
length cables, this cable should be the shortest one.
__ c.
Connect a new SPCN cable to connector J15.
__ d.
Connect a new SPCN cable to connector J16.
__ e.
Connect the power cable. Do not plug into the wall outlet. If your
power cables for the 5079 are two different lengths, connect the
longer cable to 5079–002.
__ 3.
Connect the cables to the 5079–001 (the lower unit).
__ a.
Connect the HSL cable that you installed in step 2b to HSL
connector 0.
__ b.
Connect the SPCN cable that you installed in step 2d to connector
J15.
__ c.
Connect the power cable. Do not plug into the wall outlet. If your
power cables for the 5079 are two different lengths, connect the
shorter cable to 5079–001.
__ 4.
Remove or open the back cover on your system unit.
__ 5.
Remove or open the back cover on unit Y.
__ 6.
At unit Y, remove the HSL cable at connector 1. This cable currently runs
between unit Y and your system unit.
__ 7.
Connect the HSL cable from your system unit to the HSL connector 1 on
5079–001.
__ 8.
Connect the HSL cable from 5079–002 HSL connector 0 to HSL connector 1
on unit Y.
__ 9.
Connect the SPCN cable from 5079–002 connector J15 to connector J16 on
unit Y.
__ 10.
Install or close the covers on unit Y, your 5079, and your system unit.
__ 11.
Figure 19. SPCN connections