Trigger (Fire-i 701/702/810): 
 
Parameter Min 
Typical 
Max 
7 mA
10 mA
20 mA
Ri -
270 
Ω
-
Vd -
1.08 
V
-
Rising trigger delay 
2.24 us
3.34 us
3.36 us
Falling trigger delay 
2.62 us
3.61 us
3.64 us
 
Strobe (Fire-i 701/702/810): 
 
 
 
Strobe Power 
Strobe falling delay
Strobe rising delay 
5 V 
26.8 us
2.16 us
12 V 
7.6 us
2.8 us
24 V 
3.6 us
3.4 us