Philips Video Camera Manuel D’Utilisation

Page de 34
16
17
AUTO SCAN SETUP
SCAN 01                         : AUTOSCAN01
SPEED(MODE)                 : FAST VECTOR
START ANGLE                 : 127.1, 027.7  X7
END ANGLE                     : 157.7, 080.7  X13
SCAN DIR.                       : CCW
SWAP                             : OFF
SAVE AND EXIT (ESC TO CANCEL)
HOLD DOWN CTRL KEY
WHILE SELECT POSITION.
3.4  Auto Scan  
(First Item of the Main menu / Shortcut: 
Scan)
The Auto scan supports up to 8 programmed angles at user-programmable speeds. Follow these steps to program Auto Scan:
1.  Press the 
Scan key to enter Auto Scan menu directly. Or press the Menu key to display the main menu on the monitor. Scroll to Auto Scan and push the 
    
Joystick to the right.
2.  Select an Auto Scan number by pushing the 
Joystick left or right.
3.  Twist the 
Joystick to enter the title by scrolling through the alphanumeric characters and pushing the handle to the right or left to move to the next space. 
      Press 
Enter key or push the Joystick down to finish title mode. Press HOME key in order to delete stored alphanumeric characters.
4.   Push the 
Joystick downward to select „Speed” and set the speed by twisting the Ctrl/PGM keyclockwise or counterclockwise or moving the Joystick left 
and right to select the auto scan speed.
5.  When finish entering the title and speed, select „START ANGLE” with the 
Joystick. Hold down the Ctrl/PGM key while selecting the start position and zoom  
     using the 
Joystick. Current panning position will be displayed. Release Ctrl/PGM key to complete the selection of the start position.
6.   Push the 
Joystick downward to select „END ANGLE.” Hold down the Ctrl/PGM key while moving the Joystick to select the end position and zoom. The 
end position angles should be larger than start position. Release the 
Ctrl/PGM key to complete the selection of the end position.
7.  Select Save and Exit by pushing the 
Joystick to the right. Press ESC to exit the program without saving.
NOTE:  Using the Tour mode in conjunction with preset and Auto Scan, you can make the camera travel from one preset position to another preset 
position at a specific speed. (Pan only)
a.  Before entering the Auto Scan menu, select a preset position as a starting point for Auto Scan.
     Example: 2  + Prst and do step 1 to 4. Instead of step 5, just press the Ctrl/PGM key at the start angle position, the current position will be displayed as a  
     start position.
b.  Save and exit from the menu.
c.  In normal mode, call a preset to be the end point of scan. Press 
Prst then press Scan key to enter the Auto Scan menu. Move the cursor position to 
     END ANGLE. Just press 
Ctrl/PGM key at the end angle position. Do step 7.
Example: Preset 001>002>003>004>005>006, Auto Scan 01 starts at 002, ends at 003,  Auto Scan 02 starts at 005, ends at 006.  Tour 001, 002, A01, 004, 
A02. 
1    2   2~3   4    5~6   1   2 2~3 ......
Where       : Quick move,   ~ : Programmed speed by Auto Scan.
SPEED (MODE):      NORMAL1~NOMAL9, SLOW VECTOR, FAST VECTOR
                               NORMAL1 (SLOWER) <––> NORMAL9 ( FASTER)
                               SLOW VECTOR, FAST VECTOR: Move from start point to end point including tilt and zoom simultaneously and linearly. 
                               In case of EDC-143E, EDC-142E1 and EDC-142E2, zoom is fixed at more wide angle and the zoom magnification information is not 
                               displayed.