Zebra Technologies 45537L-005 Manuel D’Utilisation

Page de 144
Getting Started
Defaulting the PSII
72
45537L-005
ZebraNet PrintServer II User Guide
04/21/2009
Test Button   
To default the PSII to factory settings using the Test button, complete these 
steps:
1.
The printer is turned off (O).
The 
Test
 button is a small hole on the bottom of the external 
PSII 
device. To press the 
Test
 button, you need to insert something small into the hole, like a paperclip.
2.
With the printer turned off, press and hold the 
Test
 button on the 
PSII
 device and turn on 
the printer.
3.
The status indicator tells you when 
PSII 
has been reset to factory defaults, as follows:
If an active network cable is connected to the 
PSII
, the status indicator turns solid 
green. When this happens, you can release the 
Test
 button.
If there is not an active network cable connected to the 
PSII
, the status indicator 
flashes green. When this happens, you can release the 
Test
 button.
For more details on status indicators, see Status Indicator
.