4.9 Specify parameters for target device 
CamTool 
Configuration Manual, 12.2004, 6AU1900-1AB32-0BA0 
4-33
 
Scaling 
You can specify the scaling for the target device here. 
 
 
Notice 
To display the scaled curve, select menu Cam > Representation parameters > Display 
scaling. 
If the scaled curve is displayed, you cannot edit the original curve. To edit the original curve 
again, reselect menu Cam > Representation parameters > Display scaling. 
 
You can set the following parameters: 
Table 4-6 
Parameters in the Scaling tab (Target Device Parameters window) 
Field/button 
Explanation/instructions 
Master axis 
 
 
Basic scaling 
Enter the basic scaling of the master axis here. The center of the scaling 
is always the coordinate origin.  
Note:  
Do not use any scaling values which are greater than 5. Greater values 
cause a roughness in the curve characteristic. 
 
Scalings 
You can specify the scalings of two ranges of the master axis here. The 
center of the scaling is the start point of the scaling range.  
Note:  
If you specify two ranges, the ranges cannot overlap. 
 
 
(Range1) 
Under From and To, enter the range that you want to scale. Under 
Factor, enter the scaling factor.  
Note:  
Do not use any scaling values which are greater than 5. Greater values 
cause a roughness in the curve characteristic. 
 
 
(Range2) 
Under From and To, enter the range that you want to scale. Under 
Factor, enter the scaling factor.  
Note:  
Do not use any scaling values which are greater than 5. Greater values 
cause a roughness in the curve characteristic. 
 
Offset 
You can enter a factor for the offset of the master axis here. If you have 
specified a scaling, the offset applies to the scaled curve. If you have not 
specified a scaling, the offset applies to the unscaled curve.