ICP DAS USA IM-30 Manuel D’Utilisation

Page de 109
Level Controlled Exposure Mode 
led mode is selected, the length of the exposure is 
determined by Ex-Trig signal alone. If the camera is set for rising edge 
When level control
triggering, exposure begins when the Ex-Trig signal rises and continues 
until Ex-Trig signal falls. If the camera is set for falling edge triggering, 
exposure begins when Ex-Trig signal falls and continues until Ex-Trig signal 
rises. 
 
Figure 1-12: Level Controlled Exposure with rising edge triggering 
 - 
16