MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming with SPM 
2-59
Upgrading the System 
2
NOTE:
MERLIN II Communications System programming cannot be 
upgraded to this communications system. The new communications 
system must be completely reprogrammed.
Before You Begin
2
Before you begin the upgrade to Release 7.0, you will need the following items:
Any version of DOS SPM or WinSPM to backup system programming 
information.
WinSPM Release 2.0 or later which contains SPM Version 7.15 or later to 
convert and restore system programming information.
— If SPM is already installed, the 
Welcome
 
to
 
SPM
 screen that 
appears when you start SPM identifies the version on both the last 
line of the console simulation window and in the upper left corner of 
the screen. If you are working with Version 7.15, 
V7
 appears in the 
upper left-hand corner of the screen and 
Version
 
7.15
 appears on 
the last line of the console simulation window.
— The version of UNIX SPM packaged with Intuity does not support 
conversion. The most current version of DOS or UNIX SPM is 
available for download from the NSAC bulletin board.
A CKE4 or later processor module (if one is not already installed in the 
system).
An R7.0 Forced Installation PCMCIA Memory Card.
NOTES:
If a new processor module is installed as part of the upgrade procedure, 
the system software is already installed. The R7.0 Forced Installation 
Memory Card is required only if you are upgrading a system and the 
processor module is not replaced.
Releases 1.0/1.1 and 2.0/2.1 that are being upgraded to Release 7.0 
require a new CKE4 processor board. Also, all earlier releases (1.0 to 
6.1) with a CKE3 or earlier processor module must be upgraded to the 
new Release 7.0 CKE4 processor. The processor name appears on the 
label on the front of the module. If ‘CKE4’ does not appear on the label, 
the module must be upgraded.
The 016 MLX module requires a CKE4 or later processor module. The 
processor name appears on the label on the front of the module. If 
‘CKE4’ does not appear on the label, the module must be upgraded.