Honeywell 128BPTSIA Manuel D’Utilisation

Page de 80
 
 
– 51 – 
Programming Device Timers 
General Information 
Device timers consist of an ON time & an OFF time, and selected days of the 
week in which they are active. There are up to 20 timers that can be used to 
control various devices, such as lights or appliances. Your installer will have 
programmed the appropriate devices into the system (up to 96 devices can be 
programmed).  
Each timer controls a single device (designated as an output number) that 
you select. For example, timer 1 might be set to turn the porch lights on at 
7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air 
conditioner Monday-Friday at 4:30pm to cool the premises before you arrive 
at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If 
desired, different timers can control the same device. For example, timer 2 
could be used Monday-Friday as in the previous example, and timer 3 could 
be set to turn the air conditioner on and off at different times Saturday and 
Sunday. 
To enter the device timer menu mode:  
Enter your security code, then press the  #  key followed by 83. 
OUTPUT TIMER # ? 
01-20,00=QUIT 01 
Up to 20 timers can be programmed. Each timer 
is identified by a number 1-20. Enter the desired 
timer number to be programmed (1-20). Press * 
to accept entry. 
06 07:00P 11:45P 
PORCH LITE    04 
If that timer number has already been 
programmed, a summary screen will appear. In 
this example: 
  06 = Timer # 
  04 = Output Device # affected by this timer  
  PORCH LITE = Output Descriptor for Device 4 
  07:00PM = Start Time; 
  11:45PM = Stop Time 
Press * to continue.  
See your installer for 
device numbers.
 
00 ENTER OUTPUT# 
 00 
Enter the desired output device number (1-96). 
As the number is entered, the device's description 
will appear. 
To delete a previously programmed timer, enter 
00 as the output number.