ICOM I706MKTMG Manuel D’Utilisation
44
5
MEMORY AND SCAN OPERATION
➀
Select VFO mode, then set a frequency.
➁
Close the squelch with [SQL].
➂
Set the desired memory channel as the watching
channel.
channel.
➃
Select S2, then push [
(F-2)
PRI] to start the watch.
• Decimal point blinks while scanning.
➄
When the scan detects a signal, the scan pauses
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
for 10 sec. or until the signal disappears, depend-
ing on the resume setting.
➅
To cancel the scan push [
(F-2)
PRI].
Note: The paused condition when detecting a signal
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
differs depending on the scan resume condition.
resume on: pauses for 10 sec.
resume off: pauses until the signal disappears.
➀
Select memory mode.
➁
Close the squelch with [SQL].
➂
Select S2, then push [
(F-1)
SCN] to start the mem-
ory scan.
• Decimal point blinks while scanning.
➃
Push [
(F-2)
SEL] to change the memory scan to
select memory scan.
• Push [
(F-2)
SEL] for 2 sec. to clear all select memory
channels.
➄
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
pauses depending on the resume setting.
➅
To cancel the scan push [
(F-1)
SCN].
Note: Two or more memory channels must be desig-
nated as select memory channels for select memory
scan to start.
nated as select memory channels for select memory
scan to start.
S2 SCN SEL V/M
Select
memory mode
memory mode
Designate
“S.”
“S.”
F-1
F-2
Push [
(F-1)
SCN], then [
(F-2)
SEL].
CH
S
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
➀
Select memory mode.
➁
Close the squelch with [SQL].
➂
Select S2, then push [
(F-1)
SCN] to start the scan.
• Decimal point blinks while scanning.
➃
When the scan detects a signal, the scan stops or
pauses depending on the resume setting.
pauses depending on the resume setting.
➄
To cancel the scan push [
(F-1)
SCN].
Note: Two or more memory channels must be pro-
grammed for memory scan to start.
grammed for memory scan to start.
S2 SCN SEL V/M
Select
memory mode
memory mode
F-1
then push [
(F-1)
SCN]
CH
MEMO
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
➀
Select VFO mode.
➁
Select the desired operating mode.
• The operating mode can also be changed while scan-
ning.
➂
Set [SQL] open or closed.
• See page a left for squelch condition.
➃
Select S2, then push [
(F-1)
SCN] to start the scan.
• Decimal point blinks while scanning.
➄
When the scan detects a signal, the scan turns
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
OFF, pauses or ignores it depending on the
resume setting and the squelch condition.
• During scan [TS] can be used only when resume is ON.
➅
To cancel the scan push [
(F-1)
SCN].
Note: If the same frequencies are programmed into
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.
the scan edge memory channels 1A and 1B, pro-
grammed scan does not start.
■ Programmed scan operation
■ Memory scan operation
■ Select memory scan operation
S2 SCN PRI V/M
Select
VFO mode
VFO mode
Select watching
channel
channel
F-2
Push [
(F-2)
PRI].
CH
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
VFO A
■ Priority watch
CH
VFO A
P
O
S1
5
5
3
7
9
20
40
10
60dB
USB
S2 SCN PRI V/M
Select
VFO mode
VFO mode
F-1
then push [
(F-1)
SCN]