Home Automation SECURITY SYSTEM Manuel D’Utilisation

Page de 82
 
When you specify that the event button is activated at the start of the delay by pressing the 1 (START EXIT) key, the mode is 
prefixed by "A-" for "arming into". 
 
 
 
 
WHEN AWAY:          (END OF DELAY)           
 
 
 
 
WHEN A-AWY:         (START OF DELAY) 
 
When the system is armed in the Day (instant) or Night (delay) mode, buttons for the Day and Night modes are executed, 
respectively. 
 
Selecting 2 (CODE) allows you to specify that the event button is activated only when a particular code is used.  You will be 
prompted to enter the code: 
 
 
 
 
ENTER USER CODE:
 
 
 
 
1-16             0=ALL 
 
 
You should enter the user code by entering the code number followed by the ' # ' key or by using the arrow keys to scroll through 
a list of code names. 
 
 
 
 
WHEN C1 AWAY:
 
   1=DELAY 
2=CODE
 
 
 
 
 
WHEN C1 A1 AWAY:
 
 
 
 
1=START EXIT  2=END EXIT 
 
Zone Event Buttons 
 
Pressing the 3 (ZONE) key allows you to select the event button for a zone activation event.  You are first prompted to enter the 
desired zone number: 
 
 
 
 
ZONE:
 
 
 
 
ENTER ZONE             
↓ 
 
The zone number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of zones.  The 
desired zone is then displayed and you are prompted to specify the state that activates the event button: 
 
 
 
 
WHEN Front Door:
 
 
 
 
0=SECURE    1=NOT RDY 
 
All On/Off Event Buttons 
 
 
Pressing the 4 (ALL) key allows you to specify an event button activated by issuing an All On or an All Off command, issuing a 
Leviton Scene command, or issuing a UPB Link command.  You are first prompted to specify whether the event button is for All 
Lights On, All Off, Leviton Scene, or UPB Link: 
 
 
 
 
ALL
 
   0=OFF 
1=ON 
2=SCN 
3=LINK
 
 
If area arming is being used, you will be prompted to specify the desired area: 
 
 
 
 
AREA:
 
 
 
 
ENTER AREA       0=ALL 
  
 
If Leviton Scene is selected, you must first specify the scene number: 
 
 
 
 
ENTER SCENE: 
   1-64 
 
Then select the specified command Off, On, or Set. 
 
If UPB Link is selected, you must first specify the link number: 
 
   ENTER 
LINK: 
   1-250
 
 
52