Emerson F-SERIES SENSOR Manuel D’Utilisation

Page de 26
Sensor Installation: F-Series
9
Determining a Location
Figure 6
F-Series sensor ambient and process temperature limits (all models except
high-temperature and extreme high-temperature models) 
Maximum process temperature in °F (°C)
Mount electronics remotely; use junction box
–148 (–100)
–112 (–80)
–76 (–60)
–40 (–40)
–4 (–20)
32 (0)
68 (20)
104 (40)
140 (60)
176 (80)
–148 (–
100)
–76 (–60)
–4 (–20)
68 (20)
140 (60)
248 (120)
91 (33)
Mount electronics remotely; use junction box
Notes:
1. When ambient temperature is below –40 °F (–40 °C), a core processor must be heated to bring its local ambient 
temperature to between –40 °F (–40 °C) and +140 °F (+60 °C). Long-term storage of electronics at ambient 
temperatures below –40 °F (–40 °C) is not recommended.
2. Temperature limits may be further restricted by hazardous area approvals.
3. The temperature extender option allows the sensor case to be insulated without covering the transmitter, core processor, 
or junction box, but does not affect temperature ratings.
158 (70)
392 (200)
–112 (–80)
–40 (–40)
32 (0)
104 (40)
212 (100)
284 (140)
320 (160)
356 (180)
176 (80)
Amb
ient tem
p
erature of core p
roce
ssor or 
transm
itt
e
r in °
F
 (°
C)