DMP Electronics SCS-1R Manuel D’Utilisation

Page de 31
Digital Monitoring Products 
SCS-1R Installation Guide
22
opeRatoR’s GuIde
Host Automation
The SCS-1R Host Automation programming section allows adjustments to optimize the SCS-1R performance with 
the host automation computer.  The display shows the current setting for each prompt.  Press any top row Select 
key to clear the display and enter the new information.  
   SCS-1R MENU
HOST AUTOMATION
  Host Automation
Press any top row Select key to program Host Automation settings.  Press the COMMAND 
key to advance to the next programming section.  Press the Back Arrow key to return to 
the previous section.  
HOST NAME
 
 
  Host Name
Enter a Host Name up to 16 characters. When done, press Command to accept name 
and continue to START CHARACTER.  
START CHARACTER : 
NONE
  Start Character
Enter the character to be used at the start of a host message.  Enter None or 01-31.  
Default is NONE.  
CRC ERROR CHECK?
 
 
NO  yES
  CRC Error Check 
Press the far right Select key for YES, which allows each message sent to the host to be 
prefixed with an SIA CIS CRC-16.  The format is 4 hexadecimal characters. Default is NO.
SEqUENCE NUMBER?
 
  
NO  yES
  Sequence Number
Press the far right Select key for YES, which sends each message sent to the host with a 
sequence number ranging from 1 to 99. Default is NO.
TEST INTERVAL: 
MINUTES: 1
  Test Interval
Press any top row Select key to clear the display and enter the new Test Interval.  Enter 
the number of minutes, 1 through 60, between communication test messages (S99) of 
the SCS-1R Receiver and host computer.  Default is 1 (one).
ACKNOWLEDGE 
TIMEOUT: 03
  Acknowledge Timeout
Press any top row Select key to clear the display and enter the new Acknowledge 
Timeout.  This is the time in seconds, 1 through 15, the SCS-1R waits for a host 
acknowledgment of a message before transmitting it again.  Default is 3 (three).
LINE NUMBER
LENGTH: 0
  Line Number Length
Press any top row Select key to clear the display and enter the new Line Number 
Length.  Enter the number of decimal ASCII characters, 0 (zero) through 2, used to 
report the SCS-1R Receiver signal line number.  Default is 0 (zero).  
RETRIES TO 
FAILURE: 5
  Retries to Failure
Press any top row Select key to clear the display.  Enter the number of attempts, 
between 1 and 15, the SCS-1R makes to transmit a message to the host computer.  
When this number is reached, the SCS-1R begins manual acknowledgement operation.  
Default is 5 (five).
Serial Ports
The SCS-1R Serial Ports section allows you to make adjustments to the Host Output, Activity Log, and Print 
Operation Serial Port.
   SCS-1R MENU
SERIAL PORTS
  Serial Ports
Press any top row Select key to program the Serial Port settings.  Press the COMMAND 
key to advance to the next programming section.  Press the Back Arrow key to return to 
the previous section.  
HOST OUTPUT BAUD   
RATE: 9600
  Host Output Baud Rate
Press any top row Select key to change the Host Output Baud Rate. Enter 300, 600, 
1200, 2400, 4800, 9600, or 19200. Press the Command button to accept. Default is 9600.
ACTIVITy LOG BAUD 
RATE: 1200
  Activity Log Baud Rate
Press any top row Select key to change the Activity Log Baud Rate. Enter 300, 600, 1200, 
2400, 4800, 9600, or 19200. Press the Command button to accept. Default is 1200.
PRINT OPERATION:    
ALWAYS
  Print Operation 
Press any top row Select key to change the Print Operation.  Select ALWAYS to enable 
the Activity Log output for all system events. Select NEVER to disable the Activity Log. 
Select FAIL to enable only when Host Automation has failed and is not acknowledging 
messages from the receiver.
PRINT OPERATION  
ALWyS NEVER FAIL