Serial Communications
Section 6-1
Settings
CJ1M (Master) PLC Setup
Note
(1) Automatically allocates 10 words (A hex) when the default setting of 0
hex is used.
(2) Connection to the FQM1 is not possible at 115,200 bits/s.
FQM1 (Slave) System Setup
 
Note
The settings are made using CX-Programmer Ver. 5.0
@ menus.
6-1-5
Serial Gateway
Serial Gateway 
Function
Servo parameters and other data can be read and written from NS-series PTs
or personal computers (applications that operate on the CX-Server) to Servo
Drivers that are connected to the FQM1 Coordinator Module's RS-422A port.
This function can be executed by setting the FQM1 Coordinator Module’s RS-
422A serial communications mode to Serial Gateway.
RS-422A-compatible 
Servo Drivers
OMRON W-series and OMRON SMARTSTEP Servo Drivers.
System Configuration
Example: Accessing a W-series or SMARTSTEP Servo Driver from Smart
Active Parts on a NS-series PT using an NT Link
Item
Address
Set value
Default
Refresh timing
Word
Bits
RS-232C 
port setting
Serial communica-
tions mode
160
08 to 11
8 hex: Serial PLC Links 
Polling Unit
0 hex
Every cycle
Port baud rate
161
00 to 07 
00 to 09 hex: Standard
(0A hex: High-speed can-
not be used.)
00 hex
Link method
166
15
ON:
Polling Unit links
(OFF: Complete links
cannot be used.)
0
Number of link 
words
04 to 07 
1 to A hex
0 hex (See 
note 1.)
Highest unit num-
ber
00 to 03 
0 to 7 hex
0 hex
Item
Set value
Default
Refresh timing
RS-232C port 
settings
Mode
7 hex: PC Link (Slave)
Host Link
Every cycle
Baud
00 to 09 hex: Standard
(0A hex: High-speed cannot be used.)
Standard 
(38,400:1, 8, 1, 0)
PC Link Unit No.
0 to 7 hex
0 hex