The three terminals of the BUS connector should be wired in parallel via either a daisy chain 
connection or terminal block split. The three contacts of the phoenix connector are as follows from left 
to right. 
 
1.  Sync 
2.  Master Mute 
3.  Ground 
 
Set one Base Station as the Primary device by putting DIP switch #1 to the ‘Off’ position. The other 
units must be set as Secondary devices by putting DIP switch #1 to the ‘On’ position. In this 
configuration, the Primary device manages the entire system, distributing microphone transmission 
across available channels to maintain frequency integrity, and coordinating system muting.  
 
Primary (DIP switch 1, Off – default): This designates the Base Station as the master control unit.  
 
Secondary (DIP switch 1, On): Additional base stations to be used in the same area must be 
connected via the BUS and be set to REMOTE mode to ensure synchronization of timing clocks 
between bases in order to prevent interference.  
 
 
 
 
 
Note:   Whenever a DIP switch is toggled, the base unit should be reset, or the power should be 
cycled for the switch setting to be registered.
 
Warning:  The switch must be in the ‘Primary’ position for a single Base Station system, which is the 
factory default setting. Microphones will not function if the switch is in the ‘Secondary’ position and no 
‘Bus’ cable is connected. 
The maximum number of microphone channels within a 300’ (90 meter) radius in the  Americas or 
Japan  is 16 channels (High Definition  mode) or 32  channels (Max Density  mode). The maximum 
number of channels within a 300’ (90 meter) radius for a EU or CN frequency system is 24 channels 
(High Definition  mode) or 40  channels (Max Density  mode).  (See Section Using the Revolabs HD 
Control Panel Software
Note:   Using Revolabs Executive HD systems in the same area(s) without the bases connected via 
the BUS will result in interference  
Warning:  Using the maximum number of Revolabs HD Microphones in a given will occupy 
100% of the available RF bandwidth. Any other wireless device operating in the same 
frequency could cause significant interference with the Revolabs HD Microphones. It is 
recommended that no other DECT or DECT 6.0 products be used within operational range of 
the Executive HD system(s). 
 
 
Primary (DIP#1 –off) 
Secondary (DIP#1 –on) 
Secondary (DIP#1 –on) 
3-wire BUS cable