Important 
 
 
This quick start manual is only intended for use by professional installers who have 
an adequate working knowledge of video systems! 
This manual outlines the most important information about the SIMATRIX NEO 
Alarm box. It is, however, vital that you also refer to the detailed information in the 
full operating instruction of SIMATRIX NEO. 
Installation and set-up 
 
Step 1: Provisionally connect the SIMATRIX NEO to the electrical supply 
Required power supply: TN network (to VDE 0100, section 300 or EN 60950) 
Voltage range: 110 - 240 Volt 
Once the system has been connected to the electrical supply, and assuming the 
device is in good operating the LED at the front of the unit will lit. 
To continue installation, you must now unplug all NEO components at the mains! 
Step 2: establish SysLink-connection 
Use the marked 
SysLink-cable to connect the SysLink-input of Alarm box 
(SIMNEO-A128) to the 
SysLink-output of SIMATRIX NEO main or extension bay. 
In case a second alarm box has to be installed, connect 
SysLink-input to SysLink 
output of first alarm box.   
 
Step 3: setup device adress 
First alarm box must be set to device address „2“, the second alarm box must be set 
to address „3“. 
Step 4: set config-switch 
In case the alarm box is the last device on SysLink-Bus, the switch 
R must be set 
to 
On, all other terminations must be switched Off. In case the device is not at the 
end of the SysLink-Bus, all switches must be set to 
Off. 
Step 5: change alarm base parameters 
Control software: Alarm base parameters button 
Alarm sensor settings 
Step 6: Alarm sensor to camera allocation 
Control software: Sensors / Camera groups button 
Step 7: Further programming 
If applicable, enter further parameters in order to tailor the function of the SIMATRIX 
NEO to suit individual operating needs and the rest of the system. 
Step 8: Make a back-up of the parameter settings and store the back-up close 
to the system. 
Operation and storage 
 
Do not operate or store the unit in following locations: 
• 
Extremely hot or cold places 
• 
Close to sources of strong magnetism 
• 
Close to sources of powerful electromagnetic radiation such as radios or TV   
    transmitters. 
• 
In humid or excessively dusty places 
• 
Where exposed to mechanical vibrations. 
Care and maintenance 
 
The alarm box is maintenance-free. 
Use a clean soft piece of cloth to wipe small amounts of dirt or dust from the body.   
Specifications 
 
Alarm Inputs: 
128 Alarm Inputs, (4 x 32 Inputs) 
Input resistance:   
2,2 Kilo Ohm   
Threshold:   
2,5 V DC 
Max. voltage: 
internal pull-up (max. 24 V DC external) 
Alarm pulse:   
min. 300 milliseconds 
Length Alarm-cable: 
max. 10 m 
Connection Alarm: 
4 x 37-pin Sub-D 
Controller 
1 RISC-Controller 
Interface   
SysLink   
Power requirement 
115 / 230 VAC (+10% / -15%), 50/60 Hz   
 
(internal switchable)   
Fuse 
2 x 125 mA slow 
Power consumption 
3 VA 
Operating temperature 
+ 5 °C to 45 °C 
Relative humidity 
30 to 85 %, non condensing 
Construction: 
19 inch chassis
, 1 HU 
Dimensions (W x H x D):  449 x 44 x 206 mm (without 19” mount)
 
 
 
 
D
a
ta
 a
n
d
 d
e
s
ig
n
 s
u
b
je
c
to
 c
h
a
n
g
e
 w
it
h
o
u
n
o
ti
c
e
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
©
 2
0
0
5
 S
ie
m
e
n
s
 B
u
ild
in
g
 T
e
c
h
n
o
lo
g
ie
s
F
ir
e
 a
n
d
 S
e
c
u
ri
ty
 P
ro
d
u
c
ts