Siemens IC60 Manuel D’Utilisation

Page de 40
 
Siemens Building Technologies
 
 
Fire Safety & Security Products 
 
01.2008
 
 
t the keypad will start beeping to indicate 
that learn mode has been activated. 
2. Press the ARM button 
 on the remote 
control 
t it will send a transmission signal. The 
panel will confirm if a user is found with 
the message “Found”. 
3. Press 
 to confirm. 
4. Repeat the actions 1 - 3 to follow up for all  
5 buttons (use the navigation button   to 
switch to the next user number). 
For remote control 2 take user numbers 26 - 
30 etc. 
 
Telephone connection
 
To transmit events, the system needs to be  
connected to a telephone line. Follow steps  
8 - 9 to program the telephone numbers. 
If no telephone line is connected, the dialer 
must be turned off: 
1. Press 
175
1
 t the display shows: 
“Dialer A Option 12----7-“. 
2. Press 1
 t the display shows: “-2----7-“. 
3. To check: press 
Ctrl
 simultaneously  
t  the display changes to clear text mode 
and shows “Enable Dialer No”. 
4. Press 
 to go back and continue with 
step 10 “Testing Installation”. 
 
Telephone numbers
 
The telephone numbers (max. 8) which are  
dialed in case of an event can be up to  
16 digits long. Default setting: Telephone 
number 8 is the call back number of the  
Control Monitoring Station (CMS). 
1. Telephone number 1: 
press 
181
1
 “tel.number”
 
2. Choose a reporting format for this number. 
a) Number related to a phone:  
press 
182
1
2
  
t an alarm signal will be sent out to this 
number when an event occurs. 
b) Call goes out to a CMS station: 
CID format: press 
182
1
1
 
SIA format: press 
182
1
10
 
3. Repeat actions 1 - 2 to follow up for  
telephone numbers 2 - 8 (use the naviga-
tion button   to switch to the next tele-
phone number). 
There are 11 different reporting formats that 
can be selected for each telephone number. 
The formats are listed in the Installer Manual. 
 
Identification code
 
When connected to a monitoring station you 
can program an individually identification 
code: 
Area A: press 
62
1
”code”
 
(4 digit code 0-F). 
 
Testing Installation
 
To test the strength of the signal received on 
the panel: press 
200
14
 
Any time a signal is detected, the keypad 
beeps and displays the received signal 
strength in % for 30 sec. 
To test all detectors on their function and  
transmission range, change to walk test 
mode. 
 In the walk test mode the panel will not 
send out any alarms and the working 
range will be less than in the normal op-
erating mode - EN50131 requirement. 
1. Start walk test: press 
200
6
 
t the keypad will start beeping to indicate 
that walk test mode has been activated. 
2. Activate the installed detectors with a  
magnet  
t it will send a transmission signal (for more 
details see Installation Instruction of the 
detector). The panel will give a notification 
signal each time a detector signal is re-
ceived and will show the detector number 
on the display. 
3. To end this mode: press 
.  
t this will take you back to the normal mode. 
4. To check out all received signals in event 
log: press
5. To clear events in the log: press 
 or  
enter the installer code (see User Manual 
3.15.3). 
The programming is finished now and the  
system ready to operate.  
Don’t forget to reconnect the internal siren!