Siemens SK5 Manuel D’Utilisation

Page de 6
 
General - English 
 
The security unit SK5 is used in high security areas. It prevents unauthorised 
persons from opening the electric release by connecting battery voltage to 
outgoing conductors.  
The SK5 is suitable to all SiPass Entro products, which is furnished with a tamper 
switch for external connection. E.g. Bewacard, Bewatel, Bewacom and Telecode. 
The security unit SK5 includes a relay that breaks the connection between the 
opening relay and the electric release when the housing for the card reader or door 
entry phone, is opened or removed from the wall. At the same time a buzzer is 
activated in the SK5.  
The unit is restored by the red button when the housing is closed again. 
1.1 Installation 
 
 
1.  The actual product to be secured. Can be codelock, Cardreader or Door entry phone, which is 
furnished with a tamper switch for external connection.  
Note! For terminal numbers on connection board, see technical information for each product. 
2.  Power Supply 12-24V DC. 
3.  Control signal from door opening relay (shown at rest). 
4.  Control signal from tamper switch. (Breaks when housing is opened). Disconnects outgoing signal 
from SK5. 
5.  Outgoing signal to lock. If a voltage free contact is required, for example to control a motor lock, 
the relay E7 (or similar) must be connected to SK5 terminal nos. 5 and 6. 
6.  Alarm output relay. Connects to alarm system or the like. Changes at tamper attempt. 
7.  Reset of buzzer. 
8.  Door opening relay in actual product. 
9.  Tamper switch in actual product. 
1.2 Technical 
specifications 
 
Power supply: 
12-24V DC 
Dimensions: 
50 x 50 x 30 mm. (HxWxD)