The following message is displayed when attempting to upload an incorrect file format.
Export language file: Click to export language strings. VIVOTEK provides nine languages: English, 
Deutsch, Español, Français, Italiano, 日本語, Português, 簡体中文, and 繁體中文�
Update custom language file: Click 
Browse… and specify your own custom language file to upload.
Export configuration file: Click to export all parameters for the device and user-defined scripts. 
Update configuration file: Click 
Browse… to update a configuration file. Please note that the model and 
firmware version of the device should be the same as the configuration file. If you have set up a fixed IP 
or other special settings for your device, it is not suggested to update a configuration file.
Export server staus report: Click to export the current server status report, such as time, logs, 
parameters, process status, memory status, file system status, network status, kernel message ... and so 
on�
Tips:
•  If a firmware upgrade is accidentally disrupted, say, by a power outage, you still have a last resort 
method to restore normal operation. See the following for how to bring the camera back to work: 
 
 
Applicable scenario:
(1) Power disconnected during firmware upgrade.
(2) Unknown reason causing abnormal LED status, and a Restore cannot recover normal working 
condition�  
 
You can use the following methods to activate the camera with its backup firmware:
(1) Press and hold down the reset button for at least one minute�
(2) Power on the camera until the Red LED blinks rapidly�
(3) After boot up, the firmware should return to the previous version before the camera hanged. (The 
procedure should take 5 to 10 minutes, longer than the normal boot-up process)� When tthis 
process is completed, the LED status should return to normal�