Avaya 03-300430 Manuel D’Utilisation

Page de 2574
Communication Manager Maintenance-Object Repair Procedures
1138 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: 
Descriptions and Error Codes (Multicarrier)
Always investigate tests in the order presented in the following table. By clearing error codes 
associated with one test, you may clear errors generated from other tests in the sequence.
Table 390: EMG-XFER Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each 
appropriate test’s description, and follow its recommended procedures.
0
Any
Any
Any
test environment UU
1
0
Emergency Transfer 
query (#124)
MAJ
ON
test environment UU r 3
257
0
Emergency Transfer 
query (#124)
WRN
ON
test environment UU r 3
Table 391: System Technician-Demanded Tests: EMG-XFER (Multicarrier Cabinets) 
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Battery & Battery Charger Query test (#5) (
)
X
X
ND
AC Power Query test (#78) (
X
X
ND
OLS Query test (Carrier E) (#127) (
X
X
ND
OLS Query test (Carrier D) (#127) (
X
X
ND
OLS Query test (Carrier A) (#127) (
X
X
ND
OLS Query test (Carrier B) (#127) (
X
X
ND
OLS Query test (Carrier C) (#127) (
X
X
ND
Emergency Transfer Query test (#124)
X
X
ND
Cabinet Sensors Query test (#122) (
X
X
ND
 1 of 2