MODEM-PT (Modem Pool Port)
Issue 1 June 2005
1695
 
Modem Pool Audit Test (#99)
This audit updates the Modem Pool conversion resource status contained in the TN758 Pooled 
Modem circuit pack’s microprocessor. It does not test the Pooled Modem circuit pack, so there 
are no FAIL codes. The audit can only be performed on idle conversion resources. If the 
conversion resource is in use, the audit aborts.
Table 625: Test #99 Modem Pool Audit Test 
Error
Code
Test
Result
Description / Recommendation
None
ABRT
The system was not able to allocate every necessary resource to execute 
this test. An ABORT simply indicates that the conversion resource was in 
use when the audit was performed. No repair action is necessary unless 
the conversion resource was known to be idle during the test (amber 
in-use LED was off) or was busied out before the test was run. In that 
case, a TN758 failure condition may exist and the following procedure 
should be used:
1. Busyout both of the TN758 Pooled Modem conversion resources on 
the circuit pack containing the failing conversion resource.
2. If the test continues to abort, replace the Pooled Modem circuit pack 
and retest.