Page de 2574
UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 June 2005
2429
 
 2
FAIL
The UDS1 interface circuit pack is reporting a Yellow F5 fault alarm. There 
is a fault in the User-Network interface from the user (PBX) to the network. 
An out-of-frame condition occurs on the remote DS1 endpoint.
If the UDS1 connects to a T1 network facility:
1. Verify that both endpoints of the DS1 link are administered using the 
same signaling mode, framing mode, and line coding.
2. Contact T1 Network Service to diagnose the remote DS1 endpoint.
3. Check the physical connectivity of the DS1 Interface circuit packs and 
cable.
4. Replace the local UDS1 Interface circuit pack and repeat the test.
If the UDS1 connects to a line-side terminating device such as a PRI 
terminal adapter:
1. Verify that the switch DS1 and the line-side terminating device are 
administered using the same signaling mode, framing mode, and line 
coding.
2. Investigate the maintenance status of the line-side terminating 
device. Refer to the 'Line-Side Terminating Device Operating Manual' 
for information.
3. Contact the vendor of the line-side terminating device to diagnose the 
equipment.
4. Check the physical connection of the UDS1 Interface circuit pack to 
the terminating device. Check premise distribution system (or 
intra-premise wiring) for physical connection failures.
5. Replace the local UDS1 Interface circuit pack and repeat the test.
 
PASS
Neither a Yellow alarm nor a Remote Multiframe Alarm nor a F5 state 
alarm is being received from the remote DS1 endpoint.
Table 861: Test #141 Yellow Alarm Inquiry Test  (continued)
Error
Code
Test
Result
Description / Recommendation