Conference Circuit Test (#7)
The Conference Circuit test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function. The NPE is instructed to listen to several different tones and
conference the tones together. The resulting signal is then measured by a tone detector port. If
the level of the tone is within a certain range, the test passes.
perform the conferencing function. The NPE is instructed to listen to several different tones and
conference the tones together. The resulting signal is then measured by a tone detector port. If
the level of the tone is within a certain range, the test passes.
2053
ABRT
At least one of the following errors is found on the DS1 circuit pack:
●
1281 – Loss of signal
●
1793 – Blue alarm
●
2049 – Red alarm
●
2305 – Yellow alarm
●
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the
procedures given in the
on page 2374 maintenance
documentation for the listed error types.
FAIL
The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
Table 328: Test #6 NPE Crosstalk Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
3 of 3
Table 329: Test #7 Conference Circuit Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1 of 3