Bosch D625 Manuel D’Utilisation

Page de 48
D623 Series/D625 Series | User's Guide | Control Panel Event Descriptions 
 
Bosch Security Systems | 9/04 | 46841E 
35 
 
 
Table 8:  Control Panel Event Descriptions (continued) 
 
Event # 
Event 
Description 
Event # 
Event 
Description 
86 
AllCom Low 
Signl 
Low signal strength detected on 
alternate communication device. 
110 
Output Set, 
Skd 
Relay set by sked. 
87 Missing, 
Alarm 
Point assigned to point expander 
(wired or RF) not responding to 
control panel status poll while 
system is armed. 
111 Output 
Set, 
RAM IV 
Relay set by RAM IV. 
88 
Missing, 
Trouble 
Point assigned to point expander 
(wired or RF) not responding to 
control panel status poll while 
system is armed. 
112 
Rstrl, Tamper 
Restoral from alarm, Tamper point 
type. 
89 
Open, Skd 
Opening by sked. 
113 
Rstrl, 
Emergency 
Restoral from alarm, Emergency 
point type. 
90 
Open, RAM 
IV 
Opening by RAM IV. 
114 
Rstrl, Panic 
Restoral from alarm, Panic point 
type. 
91 
Open, Usr 
Opening by user, by ID reported. 
115 
Rstrl, Invisible 
Restoral from alarm, Invisible point 
type. 
92 
Open, KS 
Opening by keyswitch. 
116 
Rstrl, 
24-hr Burg 
Restoral from alarm, 24-hour burglary 
point types. 
93 Open, 
Skd, 
Alarm 
Opening after alarm event by sked. 
117 
Rstrl, Cntrl, Dly 
Restoral from alarm, controlled point 
types. 
94 
Open, RAM 
IV, Alarm 
Opening after alarm event by 
RAM IV. 
118 
Rstrl, Cntrl 
Restoral from alarm, controlled point 
types. 
95 Open, 
Usr, 
Alarm 
Opening after alarm event, ID 
reported. 
119 
Rcvr Jam 
Jammed condition detected on 
premises RF receiver. 
96 
Open, KS, 
Alarm 
Opening after alarm event by 
keyswitch. 
120 
Rcvr Jam Rstl 
Jammed condition detected on 
premises RF received cleared. 
97 Point 
Opening 
Point opened by Independent 
Point Control device. 
121 RF 
Battery 
Low 
Low battery detected on premises 
RF transmitter. 
98 
Params 
Changed 
Panel parameters changed. 
122 
RF Battery 
Rstl 
Low battery condition detected on 
premises RF transmitter cleared. 
99 Phone 
Line 
Fail 
Phone the voltage less than 3 V for 
40 sec. 
123 
RF  Tamper 
Trbl 
Premises RF Transmitter Tamper 
Trouble. 
100 
Phone Line 
Rstl 
After Phone Line Fail event, phone 
line voltage detected at greater 
than 
3 V for 40 sec. 
124 
RF Tamper 
Rstl 
Premises RF Transmitter Tamper 
Restoral. 
101 
Bad Call to 
RAM IV 
Panel attempted to call RAM IV but 
was unsuccessful. 
125 
SDI Missing 
SDI device not responding to 
polling. 
102 
RAM IV 
Access Fail 
RAM IV attempted to connect to 
control panel but was 
unsuccessful. 
126 
SDI Missing, 
Rstl 
SDI device declared as missing 
now responding to polling. 
103 RAM 
IV 
Access OK 
RAM IV successfully connected 
and disconnected from control 
panel. 
127 
SDI Tamper 
Tamper open on SDI Device 
Tamper. 
104 
Re-Boot, 
Panel 
Normal start-up or reset with 
installer switch. 
128 
SDI Tamper, 
Rstl 
SDI Device Tamper restored. 
105 
Re-Boot SDI 
Unexpected reset (reboot) from 
SDI device. 
129 
SDI Trouble 
Trouble detected on SDI device. 
106 
Output Reset, 
Usr 
Relay reset by user. 
130 
SDI Trouble, 
Rstl 
SDI (option bus) device trouble 
condition cleared. 
107 Output 
Reset, 
Skd 
Relay reset by sked. 
131 
SDI Over 
Current 
Over current condition detected on 
SDI device.