TROUbLESHOOTING
Continued
POSSIBLE CAUSE
1. Control  knob  not  fully 
pressed in
2. Control knob not pressed in 
long enough
3.  Equipment shutoff valve not 
fully open
4. Thermocouple  connection 
loose at control valve
5. Pilot  flame  not  touching 
thermocouple, which allows 
thermocouple to cool, caus-
ing pilot flame to go out. This 
problem could be caused by 
one or both of the following:
  A) Low gas pressure
  B) Dirty or partially clogged 
ODS/pilot
6. Thermocouple damaged
7. Control valve damaged
1. B u r n e r   o r i f i c e ( s )   i s 
clogged
2. Inlet  gas  pressure  is  too 
low
1. Manifold  pressure  is  too 
low
2. B u r n e r   o r i f i c e ( s )   i s 
clogged
1. Burner orifice(s) is clogged 
or damaged
2. Burner damaged
3. Gas regulator defective
1. Plaque damaged
2. Inlet  gas  pressure  is  too 
low
3. Control  knob  set  between 
locked positions
1. Residues from manufactur-
ing processes
1. Metal  expanding  while 
heating or contracting while 
cooling
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep 
control knob pressed in 30 
seconds
3. Fully open equipment shut-
off valve
4. Hand  tighten  until  snug, 
then tighten 1/4 turn more
5. A) Contact local natural or 
propane/LP gas company
  B)  Clean  ODS/pilot  (see 
Cleaning,  page  16)  or  re-
place ODS/pilot assembly
6. Replace pilot assembly
7. Replace control valve
1. Clean  burner  orifice(s) 
(see Cleaning, page 16) or 
replace burner orifice(s)
2. Contact  local  natural  or 
propane/LP gas company
1. Contact  local  natural  or 
propane/LP gas company
2. Clean  burner  orifice(s) 
(see Cleaning, page 16) or 
replace burner orifice(s)
1. Clean  burner  orifice(s) 
(see Cleaning, page 16) or 
replace burner orifice(s)
2. Replace burner
3. Replace gas regulator
1. Replace burner
2. Contact  local  natural  or 
propane/LP gas company
3. Turn  control  knob  until  it 
locks at desired setting
1. Problem will stop after a few 
hours of operation
1. This  is  normal  with  most 
heaters. If noise is exces-
sive, contact qualified ser-
vice person
OBSERvED PROBLEM
ODS/pilot  lights  but  flame 
goes out when control knob 
is released
Burner(s) does not light after 
ODS/pilot is lit
Delayed ignition of burner(s)
Burner  backfiring  during 
combustion
Burner  plaque(s)  does  not 
glow
Slight smoke or odor during 
initial operation
Heater produces a clicking/
ticking noise just after burner 
is lit or shut off