Monessen Hearth EYF18 Manuel D’Utilisation

Page de 32
65D1009
4
EYF Series Unvented Gas Log Set
IMPORTANT SAFETY INFORMATION
16.  Keep  room  area  clear  and  free  from  combustible 
materials, gasoline and other flammable vapors and 
liquids.
17.  Unvented gas heaters are a supplemental zone heater. 
They are not intended to be a primary heating appli-
ance. Water vapor produced by an unvented heater 
can create moisture problems in a home when oper-
ated for extended periods of time.
18.  During manufacturing, fabricating and shipping, various 
components of this appliance are treated with certain 
oils, films or bonding agents. These chemicals are not 
harmful but may produce annoying smoke and smells 
as they are burned off during the initial operation of the 
appliance; possibly causing headaches or eye or lung 
irritation. This is a normal and temporary occurrence.
    The initial break-in operation should last two to three 
hours with the burner at the highest setting. Provide 
maximum ventilation by opening windows or doors to 
allow odors to dissipate. Any odors remaining after this 
initial break-in period will be slight and will disappear 
with continued use.
19.  Input ratings are shown in BTU per hour and are for 
elevations up to ,000 feet. For elevations above ,000 
feet, input ratings should be reduced 4 percent for each 
1,000 feet above sea level. See the National Fuel Gas 
Code.
This  appliance  may  be  installed  in  an  after-
market,  permanently  located,  manufactured 
(mobile) home, where not prohibited by local 
codes.
This  appliance  is  only  for  use  with  the  type 
of gas indicated on the rating plate. This ap-
pliance  is  not  convertible  for  use  with  other 
gases.
0.  The  heater  and  its  individual  shutoff  valve  must  be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures 
in excess of 1/ psig (3.5 kPa).
1.  The heater must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/ psig 
(3.5 kPa).
.  Do not use this room heater if any part has been under 
water. Immediately call a qualified service technician 
to inspect the room heater and to replace any part of 
the control system and any gas control which has been 
under water.
3.  This appliance must not be used with glass doors in 
the closed position. This can lead to pilot outages and 
severe sooting outside the fireplace.
4.  Never burn solid fuels in a fireplace where a unvented 
room heater is installed.
5.  Always have a fireplace screen in place when the ap-
pliance is in operation and , unless other provisions for 
combustion air are provided, the screen shall have an 
opening(s) for induction of combustion air.
W
ARNING
Never connect unit to private (non-utility)
gas wells. This gas is commonly known
as wellhead gas.
Attention Massachusetts Residents:
This product must be installed by a licensed 
gas fitter.
CODES
Adhere to all local codes or, in their absence, the latest edition of THE NATIONAL FUEL GAS CODE 
ANSI Z3.1 or NFPA54 which can be obtained from…
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
or
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 069