Intel DG43RK LGA-775 socket DDR3 1333/1066 MHz 8GB BOXDG43RK Manuel D’Utilisation

Codes de produits
BOXDG43RK
Page de 92
Intel Desktop Board DG43RK Technical Product Specification 
74 
 
4.3 
Front-panel Power LED Blink Codes 
Whenever a recoverable error occurs during POST, the BIOS causes the board’s front 
panel power LED to blink an error message describing the problem (see Table 39). 
Table 39.  Front-panel Power LED Blink Codes 
Type  
Pattern 
Note 
Processor initialization 
complete 
On when the system powers up, then off for 
0.5 seconds. 
 
POST complete 
On when the system powers up, then off for 
0.5 seconds. 
 
BIOS update in progress  Off when the update begins, then on for 
0.5 seconds, then off for 0.5 seconds.  The 
pattern repeats until the BIOS update is 
complete. 
 
Video error 
On-off (0.5 seconds each) two times, then 
3.0 second pause (off), entire pattern repeats 
(blink and pause) until the system is powered 
off. 
When no VGA option ROM is 
found. 
Memory error 
On-off (0.5 seconds each) three times, then 
3.0 second pause (off), entire pattern repeats 
(blinks and pause) until the system is powered 
off. 
 
Thermal trip warning 
On-off (0.5 seconds each) four times, then 
3.0 second pause (off), entire pattern repeats 
(blinks and pause) until the sixteenth blink, then 
ends. 
 
4.4 
BIOS Error Messages 
Whenever a recoverable error occurs during POST, the BIOS displays an error 
message describing the problem. Table 40 lists the error messages and provides a 
brief description of each. 
Table 40.  BIOS Error Messages 
Error Message 
Explanation 
CMOS Battery Low 
The battery may be losing power.  Replace the battery soon. 
CMOS Checksum Bad 
The CMOS checksum is incorrect.  CMOS memory may have been 
corrupted.  Run Setup to reset values. 
Memory Size Decreased 
Memory size has decreased since the last boot.  If no memory 
was removed, then memory may be bad. 
No Boot Device Available 
System did not find a device to boot.