Heat & Glo LifeStyle 8000TV-OAK Manuel D’Utilisation

Page de 46
9
Heat & Glo  •  8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI  •  2058-900  Rev. L  •  08/08
A
B
C
D
E
F
G
Inches
55-7/8
1/2
79
49
Min. 1 37-3/8
22
Millimeters
1419
13
2007
1245
25
949
559
Figure 3.1  Appliance Locations
In addition to these framing dimensions, also reference the following sections:
•  Clearances and Mantel Projections (Sections 3.C and 3.D)
•  Vent Clearances and Framing (Section 6).
Framing and Clearances 
 
Note:
•  Illustrations reflect typical installations and are FOR 
DESIGN PURPOSES ONLY.
•  Illustrations/diagrams are not drawn to scale.
•  Actual installation may vary due to individual design 
preference.
Fire Risk
Provide adequate clearance:
•  Around air openings
• To combustibles
•  For service access
Locate appliance away from traffi c areas.
A. Selecting Appliance Location
When selecting a location for your appliance it is important to 
consider the required clearances to walls (see fi gure 3.1).
NOTE:   For actual appliance dimensions refer to Sec-
tion 16.
WARNING
A
B
A
C
D
E
F
D
G
D
B