DKS Enterprises 9230 Manuel D’Utilisation

Page de 57
5.3 Trouble 
Shooting 
Have a good VOM meter to check voltages and continuity.  A Meg-Ohm meter capable of checking 
up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops.  
When a malfunction occurs, isolate the problem to one of three areas: 1) the operator, 2) the loop 
system, 3) the keying devices.  Use caution when checking high voltage terminals, motor 
capacitor and the motor
 
1.  Check the input indicator LEDs.  They should only come ON when a keying device (card 
reader, push button, etc.) is activated.  If any of the input LEDs are ON continuously, this 
will cause the gate operator to hold open.  Disconnect the keying devices one at a time 
until the LED goes OFF. 
2.  Check any external secondary entrapment protection devices.  Any short or malfunction 
in these devices can cause the gate operator to stop or to hold open. 
3.  A malfunction in a loop or loop detector can cause the gate operator to hold open, or to 
not detect a vehicle when it is present over the loop.  Pull the loop detector circuit boards 
from the loop ports on the operator circuit board.  If the malfunction persists, the problem 
is not with the loop system.  For more information on trouble shooting loops and loop 
detectors, refer to your loop detector instruction sheet and to the DoorKing Loop and 
Loop Detector Information Manual. 
4.  Check to be sure that there are no shorted or open control wires from the keying devices 
to the gate operator.  If a keying device fails to open the gate, momentarily jumper across 
terminals 1 and 5 on the gate operator circuit board.  If the gate operator starts, this 
indicates that a problem exist with the keying device and is not with the gate operator. 
5.  If a three-button control station (open-close-stop) is connected to this gate operator, 
check for proper wiring.  Only a DoorKing three button control station (P/N 1200-006) can 
be used with this gate operator.  Others will cause a malfunction. 
6.  Check the high voltage supply.  A voltage drop on the supply line (usually caused by 
using too small supply voltage wires) will cause the operator to malfunction.  Refer to the 
wire size chart in section 2.1. 
TROUBLESHOOTING 
SYMPTON POSSIBLE 
SOLUTION(S) 
Operator will not 
run.  Power LED is 
OFF. 
• 
Check that power to the operator is turned ON. 
• 
Transformer may be overheated.  Turn power off and allow board to cool for several 
minutes then retest.  Check for low 120 VAC power and low voltage shorts. 
• 
Check for 120 VAC at terminals 18 and 19.  If voltage measures 0, check power.  If voltage 
measures OK, check the terminal strip or replace the circuit board. 
Operator will not 
run.  Power LED is 
ON. 
• 
If a photocell is used as a secondary entrapment prevention device, check to be sure that 
the beam is not blocked. 
• 
Momentarily jumper terminal 1 to terminal 5.  If the input LED does not come ON, check 
the terminal strip or replace the circuit board.  If LED does come ON, proceed to next 
steps. 
• 
Be sure that the chain is not too tight.  A too tight chain may cause the operator to stall. 
• 
Turn power switch OFF and remove the control board. 
• 
Place a jumper wire from terminal 18 terminal 17.  CAUTION – HIGH VOLTAGE.  Turn the 
power switch on.  The motor should run.  Turn the power switch off and remove the 
jumper. 
• 
Place a jumper wire from terminal 18 to terminal 16.  CAUTION – HIGH VOLTAGE.  Turn 
the power switch on.  The motor should run in the opposite direction.  Turn the power 
switch off and remove the jumper. 
• 
If the motor runs in both steps above, replace the control board.  If the motor does not run, 
or runs in only one direction, problem can be a bad motor, motor capacitor, wire 
connections from the control board to the motor or a bad control board. 
 
9210-065-H-8-08  
Page 