United States Stove 5700 Manuel D’Utilisation

Page de 28
 
-25- 
FACTORY DEFAULTS 
FACTORY DEFAULT SETTINGS 
 
Setting Description 
Default 
Value 
(P1) Auger Period 
Time limit for the upper auger period of 
operation.  Display in is 1/10th sec. 
16 sec 
(P2) Cold Stove Temp 
Low temperature limit that a warm stove 
must reach in order to shut down com-
pletely. 
95 deg F 
(P3) Hot Stove Temp 
Maximum temperature limit that the stove 
is allowed to reach before ceasing to feed 
fuel.  
350 deg F 
(P4) Hot Stove Hysterisis 
Temperature differential below the Hot 
Stove Temp that the stove must reach be-
fore resuming operation. 
1 deg F 
(P5) Room Air On Temp 
Minimum temperature that the stove must 
reach before the room air fan will operate. 
115 deg F 
(P6) Auger Load Time 
Time limit that the auger will feed fuel dur-
ing the start-up sequence prior to engag-
ing the automatic igniter. 
15 sec 
(P7) Igniter On Time 
Time limit that the automatic igniter is en-
gaged during the start-up sequence. 
8 min 
(P8) Start-Up Time 
Time limit that the stove will be allowed to 
operate before the Room Air On Temp 
must be reached. 
15 min 
(P9) Factory Defaults 
Selecting this variable will reset all of the 
variables to the factory defaults. 
(PA) Room Fan On Temp 
High temperature limit that will cause the 
stove to reduce the fuel feed rate by 25% 
and maximize the room air fan speed.  
290 deg 
(PB) Auger Start Operation 
Variable to control the auger fuel feed dur-
ing start-up.  (0 = On, 1 = Off). 
(PC) Auger Operation Select 
Variable to set the upper auger period of 
operation.  (0 = 4 sec, 1 = 6 sec)