Coleman FC8T-UH Manuel D’Utilisation

Page de 8
246756-CTG-C-0407
2
Unitary Products Group
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
 
A
40
26-3/4
1-1/2
1-1/4
C
20
5/8
5/8
B
24-3/4
FRONT
BOTTOM IMAGE
RETURN END
TOP IMAGE
SUPPLY END
D
4” Diameter
LEFT SIDE
RIGHT SIDE
20
30-1/8
14-3/4
5-3/8
(VENT CONNECTIONS)
POWER WIRING
7/8” HOLE
2-1/2
ACCESS
WIRING
7/8” K.O.
16
8-3/4
T’STAT WIRING
7/8” K.O.
1-1/8
2-1/4
14
23-1/2
32-1/2
2
13-3/4
GAS INLET
1-1/4 x 2-1/2
B
4” Diameter
3/4
CABINET AND DUCT DIMENSIONS
Models
CFM
Cabinet Size
Cabinet Dimension
A
B
C
D
FC8T040A12UH11
1200
A
14 1/2
13 1/4
11 1/2
10 1/8
(F,L)C8T060A12UH11
1200
A
14 1/2
13 1/4
11 1/2
10 1/8
(F,L)C8T080A12UH11
1200
A
14 1/2
13 1/4
11 1/2
10 1/8
(F,L)C8T080B16UH11
1600
B
17 1/2
16 1/4
14 1/2
11 5/8
(F,L)C8T080C16UH11
1600
C
21
19 3/4
18
13 3/8
FC8T100B12UH11
1200
B
17 1/2
16 1/4
14 1/2
11 5/8
(F,L)C8T100C20UH11
2000
C
21
19 3/4
18
13 3/8
FC8T120C16UH11
1600
C
21
19 3/4
18
13 3/8
(F,L)C8T120C20UH11
2000
C
21
19 3/4
18
13 3/8
RATINGS & PHYSICAL / ELECTRICAL DATA
Models
Input/Cabinet
High/Low
Output BTU/H
High/Low
Nominal
Airflow
Cabinet Width
AFUE
Blower
Blower 
Size
MBH
MBH
CFM
In
Hp
Amps
In
FC8T040A12UH11
40/26
32/21
1200
14-1/2
80.0
1/2
7.7
10 x 8
(F,L)C8T060A12UH11
57/42
46/34
1200
14-1/2
80.0
1/2
7.7
10 x 8
(F,L)C8T080A12UH11
80/59
64/48
1200
14 1/2
80.0
1/2
7.7
10 x 8
(F,L)C8T080B16UH11
80/59
64/48
1600
17-1/2
80.0
3/4
11.5
10 x 10
(F,L)C8T080C16UH11
80/59
64/48
1600
21
80.0
3/4
11.5
10 x 10
FC8T100B12UH11
100/65
80/53
1200
17 1/2
80.0
1/2
11.5
10 x 10
(F,L)C8T100C20UH11
100/65
80/53
2000
21
80.0
1
14
11 x 10
FC8T120C16UH11
120/78
96/64
1600
21
80.0
3/4
11.5
11 x 10
(F,L)C8T120C20UH11
120/78
96/64
2000
21
80.0
1
14
11 x 11
Models
Input/Cabinet
High/Low
Max. Outlet 
Air Temp
Low Fire
Air Temp. Rise
High Fire
Air Temp. Rise
Unit 
Amps
Max 
Over-Current 
Protect
Min. wire Size 
(awg) @ 75 ft 
one way
Operation 
Weight
MBH
°F
°F
°F
Lbs
FC8T040A12UH11
40/26
150
15-45
20-50
9.0
20
14
107
(F,L)C8T060A12UH11
57/42
160
25-55
35-65
9.0
20
14
107
(F,L)C8T080A12UH11
80/52
175
30-60
40-70
9.0
20
14
117
(F,L)C8T080B16UH11
80/59
160
25-55
25-55
12.0
20
14
129
(F,L)C8T080C16UH11
80/59
160
25-55
25-55
12.0
20
14
130
FC8T100B12UH11
100/65
170
25-55
40-70
12.0
20
14
128
(F,L)C8T100C20UH11
100/65
170
25-55
40-70
12.0
20
14
145
FC8T120C16UH11
120/78
180
25-55
45-75
12.0
20
14
145
(F,L)C8T120C20UH11
120/78
170
25-55
35-65
14.0
20
12
147