Beckett Oil Burner Manuel D’Utilisation

Page de 16
Page 4 
RWB 6104 BAFG R02
   
  Table 1 – Burner Specifi cations
Capacity
      (Note 1)
‘F’ Head  (AF & AFG)
Firing rate range:    ..............0.40 – 3.00 GPH 
Input:     .......................  56,000 – 420,000 Btu
‘L1’ Head (AFG Only)
Firing rate range: ..................0.40 - 1.10 GPH 
Input:     ..................... 56,000 – 154,000 Btu/h
‘L2’ Head  (AFG Only)
Firing rate range:  .................0.50 - 1.00 GPH 
Input:    ...................... 70,000 – 140,000 Btu/h
‘V1’ Head (AFG Only)
Firing rate range:  .................0.75 - 2.75 GPH 
Input:    .................... 105,000 – 385,000 Btu/h
Certifi cations/
Approvals
UL certifi ed to comply with ANSI/UL296 & 
tested to CSA B140.0
Fuels
U. S:    No.1 or No.2 heating oil only 
           (ASTM D396)
 Canada:   No. 1 stove oil or No. 2 furnace oil 
                 only
Electrical
Power supply:  ............... 120 volts AC, 60 Hz, 
                                 single phase
Operating load:  .......................5.8 Amps max
Motor:  ............ 1/7 hp, 3450 rpm, NEMA 48M 
                  frame PSC rotation CCW 
                  when facing shaft end
Ignition:  ... Continuous duty solid-state igniter
Fuel pump
Outlet pressure:  ..................................Note 2
Air tube
ATC code:  ...................................See Table 2
Dimensions
(with cover)
Height (maximum) ....................... 12.5 inches
Width (maximum)  .......................... 15 inches
Depth   ......................................... 9.25 inches
Air tube diameter  .......................  4.00 inches
Note 1: Approval agency listed rating for these burners is 0.40 to 
3.00 gph. However, the fi ring rate range is limited by the 
specifi c air tube combination being used. Refer to Table 2.
 Note 2.  See appliance manufacturer’s burner specifi cations for rec-
ommended pump discharge pressure.
General Specifi cations
Table 2 – Air Tube Combination (ATC) codes
Firing 
Rate 
(gph)
Head
Static 
plate 
size
Ven-
turi
ATC Codes for usable air tube lengths
(‘A’ in inches; See Figure 3.)
(min-
max)
(inch-
es)
4-1/2
5
5-3/8
6-5/8
7
7-1/4
9
10-1/2
13
16
0.50-0.75
F0
3-3/8U
None
AF44XR
-
AF53XR
AF65XR
-
AF72XR
AF90XR
AF104XR
AF130XR
A160XR
0.75-1.25
F3
2-3/4U
None
AF44XN
-
AF53XN
AF65XN
-
AF72XN
AF90XN
AF104XN
AF130XN
AF160XN
0.85-1.35
F4
2-3/4U
None
AF44WH
-
AF53WH
AF65WH
-
AF72WH
AF90WH
AF104WH
AF130WH
AF160WH
0.85-1.65
F6
2-3/4U
None
AF44YB
-
AF53YB
AF65YB
-
AF72YB
AF90YB
AF104YB
AF130YB
AF160YB
1.10-2.00
F12
2-3/4U
None
AF44XO
-
AF53XO
AF65XO
-
AF72XO
AF90XO
AF104XO
AF130XO
AF160XO
1.65-2.50
F22
2-3/4U
None
AF44XP
-
AF53XP
AF56XP
-
AF72XP
AF90XP
AF104XP
AF130XP
AF160XP
2.50-3.00
F31
None
None
AF44XS
-
AF53XS
AF65XS
-
AF72XS
AF90XS
AF104XS
AF130XS
AF160XS
0.50-1.10
L1
3-3/8U
8hole
-
AFG50MB
-
-
AFG70MB
-
AFG90MB
-
-
-
0.50-1.00
L2
2-3/4U
8hole
AFG50MP
-
-
AFG70MP
-
AFG90MP
-
-
-
0.75-2.75
V1
2-3/4U
8hole
-
AFG50MD
-
-
AFG70MD
-
AFG90MD
-
-
-
0.40-0.75
F0
3-1/2U
None
AF44WG
-
AF53WG
AF65WG
-
AF72WG
AF90WG
AF104WG
AF130WG
A160WG
Please read and understand the manual supplied with 
this equipment. This equipment must be installed, adjust-
ed and put into operation only by a qualifi ed individual or 
service agency that is:
Licensed or certifi ed to install and provide techni-
cal service to oil heating systems.
Experienced with all applicable codes, standards 
and ordinances.
Responsible for the correct installation and com-
mission of this equipment.
Skilled in the adjustment of oil burners using com-
bustion test instruments.
The installation must strictly comply with all applicable 
codes, authorities having jurisdiction and the latest revi-
sion of the National Fire Protection Association Standard 
for the installation of Oil-burning Equipment, NFPA 31 (or 
CSA B139 and B140 in Canada).
Regulation by these authorities take precedence over the 
general instructions provided in this installation manual.
y
y
y
y
Incorrect installation, adjustment, 
and use of this burner could result 
in severe personal injury, death, or 
substantial property damage from 
WARNING
!
Professional Service     
Required
fi re, carbon monoxide poisoning, soot or explo-
sion.