Beckett Oil Burner Manuel D’Utilisation
Page 4
RWB 6104 BAFG R02
Table 1 – Burner Specifi cations
Capacity
(Note 1)
(Note 1)
‘F’ Head (AF & AFG)
Firing rate range: ..............0.40 – 3.00 GPH
Input: ....................... 56,000 – 420,000 Btu
Firing rate range: ..............0.40 – 3.00 GPH
Input: ....................... 56,000 – 420,000 Btu
‘L1’ Head (AFG Only)
Firing rate range: ..................0.40 - 1.10 GPH
Input: ..................... 56,000 – 154,000 Btu/h
‘L2’ Head (AFG Only)
Firing rate range: .................0.50 - 1.00 GPH
Input: ...................... 70,000 – 140,000 Btu/h
‘V1’ Head (AFG Only)
Firing rate range: .................0.75 - 2.75 GPH
Input: .................... 105,000 – 385,000 Btu/h
Firing rate range: ..................0.40 - 1.10 GPH
Input: ..................... 56,000 – 154,000 Btu/h
‘L2’ Head (AFG Only)
Firing rate range: .................0.50 - 1.00 GPH
Input: ...................... 70,000 – 140,000 Btu/h
‘V1’ Head (AFG Only)
Firing rate range: .................0.75 - 2.75 GPH
Input: .................... 105,000 – 385,000 Btu/h
Certifi cations/
Approvals
UL certifi ed to comply with ANSI/UL296 &
tested to CSA B140.0
Fuels
U. S: No.1 or No.2 heating oil only
(ASTM D396)
Canada: No. 1 stove oil or No. 2 furnace oil
only
(ASTM D396)
Canada: No. 1 stove oil or No. 2 furnace oil
only
Electrical
Power supply: ............... 120 volts AC, 60 Hz,
single phase
Operating load: .......................5.8 Amps max
Motor: ............ 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW
when facing shaft end
Ignition: ... Continuous duty solid-state igniter
single phase
Operating load: .......................5.8 Amps max
Motor: ............ 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW
when facing shaft end
Ignition: ... Continuous duty solid-state igniter
Fuel pump
Outlet pressure: ..................................Note 2
Air tube
ATC code: ...................................See Table 2
Dimensions
(with cover)
(with cover)
Height (maximum) ....................... 12.5 inches
Width (maximum) .......................... 15 inches
Depth ......................................... 9.25 inches
Air tube diameter ....................... 4.00 inches
Width (maximum) .......................... 15 inches
Depth ......................................... 9.25 inches
Air tube diameter ....................... 4.00 inches
Note 1: Approval agency listed rating for these burners is 0.40 to
3.00 gph. However, the fi ring rate range is limited by the
specifi c air tube combination being used. Refer to Table 2.
specifi c air tube combination being used. Refer to Table 2.
Note 2. See appliance manufacturer’s burner specifi cations for rec-
ommended pump discharge pressure.
General Specifi cations
Table 2 – Air Tube Combination (ATC) codes
Firing
Rate
(gph)
Head
Static
plate
size
Ven-
turi
ATC Codes for usable air tube lengths
(‘A’ in inches; See Figure 3.)
(min-
max)
(inch-
es)
4-1/2
5
5-3/8
6-5/8
7
7-1/4
9
10-1/2
13
16
0.50-0.75
F0
3-3/8U
None
AF44XR
-
AF53XR
AF65XR
-
AF72XR
AF90XR
AF104XR
AF130XR
A160XR
0.75-1.25
F3
2-3/4U
None
AF44XN
-
AF53XN
AF65XN
-
AF72XN
AF90XN
AF104XN
AF130XN
AF160XN
0.85-1.35
F4
2-3/4U
None
AF44WH
-
AF53WH
AF65WH
-
AF72WH
AF90WH
AF104WH
AF130WH
AF160WH
0.85-1.65
F6
2-3/4U
None
AF44YB
-
AF53YB
AF65YB
-
AF72YB
AF90YB
AF104YB
AF130YB
AF160YB
1.10-2.00
F12
2-3/4U
None
AF44XO
-
AF53XO
AF65XO
-
AF72XO
AF90XO
AF104XO
AF130XO
AF160XO
1.65-2.50
F22
2-3/4U
None
AF44XP
-
AF53XP
AF56XP
-
AF72XP
AF90XP
AF104XP
AF130XP
AF160XP
2.50-3.00
F31
None
None
AF44XS
-
AF53XS
AF65XS
-
AF72XS
AF90XS
AF104XS
AF130XS
AF160XS
0.50-1.10
L1
3-3/8U
8hole
-
AFG50MB
-
-
AFG70MB
-
AFG90MB
-
-
-
0.50-1.00
L2
2-3/4U
8hole
AFG50MP
-
-
AFG70MP
-
AFG90MP
-
-
-
0.75-2.75
V1
2-3/4U
8hole
-
AFG50MD
-
-
AFG70MD
-
AFG90MD
-
-
-
0.40-0.75
F0
3-1/2U
None
AF44WG
-
AF53WG
AF65WG
-
AF72WG
AF90WG
AF104WG
AF130WG
A160WG
Please read and understand the manual supplied with
this equipment. This equipment must be installed, adjust-
ed and put into operation only by a qualifi ed individual or
service agency that is:
ed and put into operation only by a qualifi ed individual or
service agency that is:
Licensed or certifi ed to install and provide techni-
cal service to oil heating systems.
Experienced with all applicable codes, standards
and ordinances.
Responsible for the correct installation and com-
mission of this equipment.
Skilled in the adjustment of oil burners using com-
bustion test instruments.
cal service to oil heating systems.
Experienced with all applicable codes, standards
and ordinances.
Responsible for the correct installation and com-
mission of this equipment.
Skilled in the adjustment of oil burners using com-
bustion test instruments.
The installation must strictly comply with all applicable
codes, authorities having jurisdiction and the latest revi-
sion of the National Fire Protection Association Standard
for the installation of Oil-burning Equipment, NFPA 31 (or
CSA B139 and B140 in Canada).
sion of the National Fire Protection Association Standard
for the installation of Oil-burning Equipment, NFPA 31 (or
CSA B139 and B140 in Canada).
Regulation by these authorities take precedence over the
general instructions provided in this installation manual.
y
y
y
y
Incorrect installation, adjustment,
and use of this burner could result
in severe personal injury, death, or
substantial property damage from
in severe personal injury, death, or
substantial property damage from
WARNING
!
Professional Service
Required
fi re, carbon monoxide poisoning, soot or explo-
sion.
sion.