Figure 7 - Burner installed in appliance front
Legend
H Housing total length — 18”
J Center to bottom of housing — 10-7/8” 
K Overall housing height — 13-3/8”
Fuel unit by-pass plug
‰
The burner is shipped without the by-pass plug in-
stalled.
Intall the by-pass plug in two-pipe oil supply systems 
ONLY.
y
y
Failure to comply could cause immediate pump 
seal failure, pressurized oil leakage and the po-
tential for a fi re and injury hazard.
Do Not Install By-pass 
Plug with 1-Pipe System 
Use a two-pipe system, one-pipe system with by-pass 
loop, or remove the by-pass plug when using with a 
one-pipe system and no by-pass loop
y
Insert burner
Position the burner in the front of the appliance and loosely 
tighten the nuts on the mounting studs. The burner should 
be pitched downward 2° as shown in Figures 2 and 3.
See Figure 7. Install the pedestal support kit (recommend-
ed) by attaching the ¾” NPT fl ange (item a) to the bottom 
of the burner using the (4) #10 screws provided. Cut and 
thread (one end only) a ¾” pipe nipple (item b) with length 
10 inches less than dimension D in Figure 7. Thread the 
pipe into the fl ange. Then slip the pipe end into the fl oor 
fl ange (item c).
Secure the burner to the appliance by tightening the nuts on 
the burner fl ange mounting studs. Then secure the pedestal 
support fl oor fl ange set screw to the pipe.
‰
y
y
y
Oil supply/return lines
Install the oil tank and oil lines in accordance with all 
applicable state and local codes.
Size the oil supply and return lines using the guidelines 
given in the fuel unit literature included in the literature 
envelope. Oil line fl ow rate will equal the burner rate for 
one-pipe systems. For two-pipe systems, refer to Table 3 
for the fuel unit gear set capacity - the rate at which fuel 
is recirculated when connected to a two-pipe system. Size 
two-pipe oil lines based on this fl ow rate.
Use continuous lengths of heavy-wall copper tubing, routed 
under the fl oor where possible. Do not attach fuel lines to 
the appliance or to fl oor joists if possible. This will reduce 
vibration and noise transmission problems.
Install an oil fi lter sized to handle the fuel unit gearset fl ow 
capacity (Table 3) for two-pipe systems. Size the fi lter 
for the fi ring rate for one-pipe systems. Locate the fi lter 
immediately adjacent to the burner fuel unit.
Install two high-quality shut-off valves in accessible 
locations on the oil supply line. Locate one valve close 
to the tank. Locate the other valve close to the burner, 
upstream of the fuel fi lter.
‰
y
y
y
y
y
Connect Fuel Lines