Beckett CF1000 Manuel D’Utilisation

Page de 20
4
Form 6104 BCF10-R06
Hazard defi nitions
Intended to bring special attention to information, 
but not related to personal injury or property 
damage.
NOTICE
Indicates a potentially 
hazardous situation, 
which, if not avoided, may result in person-
al injury or property damage. 
Indicates a potentially
hazardous situation, 
which, if not avoided, could result in death, 
severe personal injury, and/or substantial 
property damage.
Indicates an imminently 
hazardous situation, 
which, if not avoided, will result in death, 
serious injury, or property damage.
Within the boundaries of the hazard warning, there will 
be information presented describing consequences if the 
warning is not heeded and instructions on how to avoid 
the hazard.
 To the Owner:
 
Thank you for purchasing a Beckett burner 
for use 
with your heating appliance.  Please pay attention to the 
Safety Warnings contained within this instruction manual. 
Keep this manual for your records and provide it to your 
qualifi ed service agency for use in professionally setting 
up and maintaining your oil  burner.
  Your Beckett burner will provide years of effi cient opera-
tion if it is professionally installed and maintained by a 
qualifi ed service technician. If at any time the burner does 
not appear to be operating properly, immediately contact 
your qualifi ed service agency
 for consultation.
  We recommend annual inspection/service of your oil 
heating system by a qualifi ed service agency. 
Agency approvals
UL listed to comply with ANSI/UL296 and certifi ed  to 
CSA B140.0.
Accepted by N.Y.C. M.E.A.
Other approvals may be available and must be specifi ed at 
time of order.
‰
‰
‰
Specifi cations
Fuels
U.S.  #1 or #2 heating 
oil only (ASTM D396)
Canada #1 stove oil or  
#2 furnace oil only
Firing range 
4.0 to 10.0 GPH
Motor   
½ HP 3450 RPM
120/60 hz standard
6.5 amps @ 120 VAC
Optional voltages:
(60 hz or 50 hz) 
• 240/1-PH
• 208/240/480/3-PH
Ignition Trans. 
120V/12,000V
Housing
Cast aluminum
Fuel unit
100 - 300 PSIG
Oil nozzle
45° - 70° solid
Shipping wt.  
75 lbs.
Dimensions   
See Figure 7 (Page 10)
(See NOTICE on 50 hz motor applications.)
LISTED
(FUEL) BURNER      
SERIAL NUMBER
050214-00000
Control Circ: 120V/60Hz 4.5A
Motor Circ: 120V/60Hz 4.0A
Model “XX”
Series (Fuel) Burner
R.W. Beckett Corp.
Elyria, Ohio
Made in the U.S.A.
For use with Group 8 . . . 
MP 1192      XX000      R00
X
X
X
X
X
X
XX000     R00
050214-00000
MFR’S SETTINGS
R.W. Beckett Construction & Setting Data
R.W. Beckett Specifi cation
Number and Revision
Boiler Manufacturer and 
Model, When Applicable
Additional Codes
General Model Information
Serial Number,Including Date Code
Rating Information
Approval Agency Symbols
Primary Group and Fuel
L0002