Beckett CF1000 Manuel D’Utilisation

Page de 20
Form 6104 BCF10-R06
7
The fuel unit nozzle port pressure is factory set at 300 psig. 
Some original equipment manufacturer burner applications 
may call for a lower pressure to obtain a required fi ring 
rate.  Do not change this pressure unless directed to do so 
by the appliance manufacturer.
Vent system
The fl ue gas venting system must be in good condition and 
must comply with all applicable codes.
Electrical supply
Verify that the power connections available are correct for 
the burner. All power must be supplied through fused dis-
connect switches.
Verify burner components —
Burner box, Model CF1000
Air tube assembly 
Mounting fl ange kit
Pedestal mounting assembly kit (recommended)
Oil nozzle, per Table 1 — Only 45° to 70° solid pattern 
nozzles are recommended unless otherwise specifi ed  by 
appliance manufacturer. (See specifi c  appliance  recom-
mendation sheet or refer to OEM Spec Guide).  Find the 
required fi ring rate in the 300 psig column (factory-set fuel 
unit pressure). Select the corresponding nozzle from col-
umn 1 (Rated gph @ 100 psig).
Verify fi ring rate
Refer to appliance manufacturer’s instructions (if available) 
for fi ring rate and nozzle selection. Otherwise, the maximum 
recommended  fi ring rate for the burner depends on the 
length of the fi ring chamber and the distance from the 
burner center to the chamber fl oor. Verify that the chamber 
dimensions are at least as large as the minimum values 
given in Figure 1. If the appliance dimensions are smaller 
than recommended, reduce the fi ring rate accordingly.
Verify air tube
The information in this section may be disregarded if the 
air tube is supplied by the appliance manufacturer.
Two tube arrangements are available –
 Tube 
A — 4.0 to 10.0 GPH per Table 2
 Tube 
B — 7.0 to 10.0 GPH per Table 2
Maximum fi ring capacity depends on the fi rebox pressure. 
Use Table 2 to verify the correct air tube type for the fi ring 
rate required. Use Tube B only when Tube A cannot pro-
vide the fi ring rate required.
See Figure 2 to verify the correct air tube length and air 
tube combination code.
y
‰
y
‰
y
‰
y
y
y
y
y
‰
y
‰
y
y
y
y
Firing Rate
Minimum Dimensions
(refractory-lined)
(wet-base boilers)
A
L
A
L
0 to 5 gph
7.0”
25.0”
7.0”
25.0”
5 to 10 gph
8.0”
35.0”
8.0”
40.0”
 Install the burner with a 2 deg. pitch as shown
E  Insertion depth
G  Air tube to inside of chamber
      0.25” +/- 0.125
T  Air tube length
D  Tube diameter
Figure 2 - Air Tube Mounting Dimensions
Figure 1. Min. Combustion Chamber Dimensions
Air Tube Length           
 
(Dimension T)
A.T.C. Codes
(A.T.C. = Air Tube Combination)
Tube A
(Dim. D = 5-1/2”)
Tube B
(Dim. D = 5-3/4”)
0
6.75”
CF66KD
CF66KE
10.25”
CF102KD
CF102KE
13.75”
CF136KD
CF136KE
17.75”
CF176KD
CF176KE