Sterling 882.00291.00 Manuel D’Utilisation

Page de 52
•  Mercury process heater contactor 
•  Process high temperature alarm light 
•  Process/regeneration heater box 
•  High temperature safety system (Process/Regeneration) 
Controller Features 
•  Mitsubishi programmable relay controller 
•  Display of process temperature set point and actual settings 
2-4 Options 
Options marked with “*” indicate options that can be factory installed or retrofitted in the 
field. 
•  * Process temperature up to 400ºF (204º C) or below 180ºF (82ºC), including 
aftercooler with dryer and silicone insulated delivery hose. 
Note: 
For below 180°F (82ºC), cooler needs to cool the 
residual heat coming out of the desiccant tank prior to 
entering the process heater box. 
•  * If the dryer is a central dry air generator, it will not have a process heater box. 
•  * Plasticizer trap (with cooling coil) in lieu of standard aftercooler (mounts outside on 
back of dryer) 
•  * Drawer magnet, stainless steel construction. 
•  * Casters, two (2) fixed and two (2) swivels. 
•  * Machine mount adapter to accommodate a dryer and corresponding hopper. 
•  * Low temperature operation below 180ºF (82ºC), includes an internal cooler. 
•  * Redundant high temperature safety circuit. 
•  * Cart with caster with hopper mounting place. 
•  * Insulated air hose for air delivery. 
•  * Audible alarm. 
•  * Dew Point monitor with digital read-out. 
2-5 Safety 
Devices and Interlocks 
This section includes information on safety devices and procedures that are inherent to the 
Dryer. This manual is not intended to supersede or alter safety standards established by the 
user of this equipment. Instead, the material contained in this section is recommended to 
supplement these procedures in order to provide a safer working environment. 
At the completion of this section, the operator and maintenance personnel will be able to do 
the following: 
•  Identify and locate specific safety devices. 
•  Understand the proper use of the safety devices provided. 
•  Describe the function of the safety device. 
15, 30, & 60 cfm Compact Dryers 
 
12