Chapter 7: Troubleshooting 
52 of 58 
 
Chapter 7:  Troubleshooting 
PROBLEM  
POSSIBLE CAUSE  
CORRECTIVE ACTION 
Little or no air coming from 
process delivery tube.  
 A.  Dirty Filters  
A. 
Clean or replace 
filters.  
 
 B. 
Desiccant beds 
contaminated by material 
or plasticizer leaking into 
the system. See Sec. 6-6. 
 
B. Replace 
desiccant 
 
C.  Blower fuse(s) blown.  
C.  Fix problem and 
Replace fuse(s). 
 D. 
Overload 
tripped. 
 
D.  Fix problem and reset  
the overload.  
 
E.    Blower fins filled with 
dust or contaminants. 
E.    Remove blower 
sideplate, clean 
baffles, replace. 
Suction in delivery tube, 
pressure from the return 
tube.  
A.  Phase is reversed  on 
power drop coming 
into the dryer. 
A. 
Stop the Dryer.  
If the dryer was connected 
to the drying hopper, check 
to see if the desiccant and 
process air heater has 
been contaminated with 
resin. If so, replace the 
desiccant and remove any 
resin carry-over. Otherwise, 
change the phase of two 
legs of the three-phase 
power drop.  Never change 
the phase at the motor 
starters unless only one of 
the two blowers is rotating 
improperly.