Sterling SDA 150-380 Manuel D’Utilisation

Page de 52
 
 
Cabinet Series Dehumidifying Dryer 
 
21 
Figure 4: 
Display Readout for Mode Settings 
                               
PV
SV
SV
SV
SV
SV
SV
SV
Menu display
Level 0 mode
Level 1 mode
Level 2 mode
Setup mode
Expansion mode
Option mode
Calibration mode
 
 
4-6  Setting the Process Air Temperature 
To change the process air temperature set point with the dryer running: 
„
  Press the Up Arrow button to increase the set point to the temperature you want. 
„
  Press the Down Arrow button to lower the set point to the temperature you want. 
„
  Press the Auto-tune button to initiate auto-tuning. 
4-7 PLC 
Controller 
The PLC controller uses an Allen-Bradley programmable logic controller (PLC). This “brick”-
type controller has 32 I/O points: twenty (20) inputs and twelve (12) outputs, all inputs and 
outputs are 115 VAC. 
All programming and logic is factory-installed on an EEPROM chip and cannot be modified. A 
battery backup retains programming if power fails. Battery life is five (5) years at room 
temperature. 
If the alarm indicator blinks intermittently, replace the battery within one week.