Sterling SDA 150-380 Manuel D’Utilisation

Page de 52
 
 
Cabinet Series Dehumidifying Dryer 
 
46 
Level 2  Cn5L input shift lower limit  
-999.9 to 999.9
°C 
0.0 Default 
 
Mode Parameter 
Setting 
range 
Default 
Factory 
setting 
Setup 
Cn-t Input Type 
0 to 21 
17 
Setup 
Cn-H Scaling Upper Limit  
Scaling Lower Limit +1 to 
9999 EU 
-100 
15
°F/-9C 
Setup 
Cn-L Scaling Lower Limit  
-1999 to SP Setting Upper 
Limit –0.1 EU 
-40
°F/-40C 
Setup 
dP Decimal Point  
0 to 3 
Default 
Setup 
CnCE Parameter Initialize 
Yes/No 
No 
Default 
Setup 
6Ut1 Control Output 1 
Assignment  
Heat/Cool/Alarm 1/Alarm 2/ 
Alarm 3/LBA 
Heat COOL 
Setup 
6Ut2 Control Output 2 
Assignment  
Heat/Cool/Alarm 1/Alarm 2/ 
Alarm 3/LBA 
AL-1 Default 
SetUp 
Sub 1 Auxiliary Output 1 
Assignment  
Alarm 1/Alm 2/Alm 3/LBA/S. 
ERR/E333 
AL-2 Default 
Setup 
ALt1 Alarm 1 Type  
0 to 11 
Setup 
AL1n Alarm 1 open in alarm 
NO/NC 
NO 
Default 
Setup 
ALt2 Alarm 2 Type  
0 to 11 
Setup 
AL2n Alarm 2 open in alarm 
NO/NC 
NO 
Default 
Setup 
6rEU Direct/Reverse 
Operation 
OR-R/OR-D OR-R 
Default 
Expansion  SL-H Set Point Upper Limit  
SP Lower Limit +1 to 
Scaling Upper Limit 
1300 
15
°F/-9C 
Expansion  SL-L Set Point Lower Limit  
Scaling Upper Limit to Sp 
Lower Limit 
-200 
-40
°F/-40C 
Expansion CntL PID/ON/OFF 
PID/ON-OFF 
PID 
ON-OFF 
Expansion 
rESt Standby Sequence 
Reset Setting Method 
0/1 0 
Default 
Expansion 
rEt Automatic Return of 
Display Mode 
0 to 99 SEC 
Default 
 
 
6-8    Restoring the E5CK Temperature Controller and Dew Point 
Meter to Factory Setup 
If preset parameters on the controller have been tampered with and it no longer properly controls 
temperature and displays dew point, you can restore the controller to factory setup.