If a system fault occurs (see Fault Code list on Page 19), the monitor responds by turning ON the front 
panel SYSTEM FAULT (yellow) light and energizing the fault relay. If the internal audible alarm is 
turned ON, it too will activate. An optional external alarm device can be connected to the fault relay to 
alert personnel that a system fault has occurred. The SYSTEM FAULT light will turn OFF only after the 
cause of the fault has been eliminated. 
A log of the alarm and fault events can be viewed using the monitor’s ALARMS and FAULTS function 
 
Display Screens 
Initial Power Up 
When first powered up all front panel lights are turned ON, and a splash screen appears showing the 
monitor’s firmware revision level. After a brief moment the Warm Up screen is display along with the 
front panel MONITOR ON light (green) blinking.  
 
 
 
The monitor takes 15 minutes to warm up; after which, the MONITOR ON light glows steady and the  
Data Display screen is displayed. 
 
Data Display Screen 
 
 
 
During normal operation, the Data Display screen shows when the monitor is performing the following 
three functions: 
MEASURE indicates that the monitor is actively monitoring for refrigerant gas. In the example screens 
shown above, the monitor is currently detecting 0 ppm of R-134a gas, and that a peak measurement of 
485 ppm has occurred.  
To reset the peak value to zero, press the ENTER button. 
PURGE is displayed when the monitor is resetting its infrared detector to a baseline of 0 ppm using 
ambient air as the gas sample. This purging process is performed on an “as needed” basis, which is 
normally once every 6 to 8 minutes.  
Note that a charcoal filter (Page 8) is present in the purge-air stream to filter out any refrigerant gas that 
would otherwise cause the baseline level to be something other than 0 ppm. 
PRES CHK is displayed when the monitor is performing an atmospheric pressure check, which is done to 
ensure the accuracy of the gas measurement under varying atmospheric conditions. This pressure check is 
performed every 30 minutes. 
 
BACHARACH INC 
HGMSZ  REV 1.0 
WARM UP 
MEASURE  00485pk 
    0ppm R134A 
PURGE    00485pk
    0ppm R134A
PRES CHK 00485pk 
   0ppm R134A